C.E. Niehoff & Co. LBCD Static/Dynamic Troubleshooting Guides User Manual

Lbcd static and dynamic tests, Lbcd static tests, Testing procedures

Advertising
background image

TG53B

Page 1 of 2

LBCD Static and Dynamic Tests

Testing Procedures

LBCD Static Tests

(Dynamic Tests on Page 2)

Before testing unit:

Remove all cables from top terminals and control har-

ness from side of unit.

TABLE 1 Pin-to-Pin Tests (See Figures 1 and 2)

METER (+) LEAD

CONNECTION

EXPECTED READING

Diode Test
Diode Test
Diode Test
Diode Test
Diode Test
Diode Test
Ohms Ω
Ohms Ω
Ohms Ω

METER (–) LEAD

CONNECTION

TESTED CIRCUIT

24 V LOAD terminal
24 V BATTERY terminal
12 V LOAD terminal
12 V BATTERY terminal
Socket A*
Socket B*
Socket A*
Socket A*
Socket A*

24 V BATTERY terminal
24 V LOAD terminal
12 V BATTERY terminal
12 V LOAD terminal
Socket B*
Socket A*
Socket C*
Socket D*
Socket E*

24 V battery circuit
24 V battery circuit
12 V battery circuit
12 V battery circuit
internal circuit
internal circuit
internal circuit
internal circuit
internal circuit

OL (blocking)
.3-.7 V (flow)
OL (blocking)
.3-.7 V (flow)
.3-.7 V (flow)
OL (blocking)
>25 K ohms
300-350 ohms
>25 K ohms

Control harness

receptacle

12 V Battery

24 V Load

12 V Load

24 V Battery

Figure 1 – N2003 Load & Battery Control Device

Figure 2 – N2003 Control Harness Receptacle

* Socket in LBCD control harness receptacle

Static tests may not diagnose all

LBCD failures. Dynamic testing

should also be performed. See

Page 2.

NOTICE

Pin

Function

TABLE 2 – N2003 Harness Plug

Pin Functions

A
B
C

D
E

Battery Ground

Chg. System Indicator Ground Signal

Battery Disconnect Ground Signal

AC In from Regulator AC Terminal

Battery Voltage Sense/Trickle Charge

METER SCALE

& SYMBOL

Advertising