C.E. Niehoff & Co. N2013 Troubleshooting Guides User Manual

Troubleshooting guide for n2013 battery isolator, Notice, Battery conditions

Advertising
background image

Page 1

TG0055A

Table of Contents

Section A: Component Description .....................................2
Section B: Basic Troubleshooting .......................................2
Section C: Advanced Troubleshooting ................................3

Battery Conditions

Until temperatures of electrical

system components stabilize, these

conditions may be observed during

cold-start voltage tests.

Maintenance/Low Maintenance Battery

— Immediately after engine starts, system volts are

lower than regulator setpoint, amps are medium.

— 3–5 minutes into charge cycle, system volts

increase, amps decrease.

— 5–10 minutes into charge cycle, system volts

increase to, or near, regulator setpoint and amps

decrease to a minimum.

— Low maintenance battery has same characteristics

with slightly longer recharge times.

Maintenance-free Battery

— Immediately after engine starts, system volts are

lower than regulator setpoint, low charging amps.

— Once charge cycle begins, low volts and low amps

are still present.

— After alternator energizes, voltage will increase

several tenths. Amps will increase gradually, then

quickly, to medium to high amps.

— Finally, volts will increase to setpoint and amps will

decrease.

The time it takes to reach optimum voltage and amper-

age will vary with engine speed, load, and ambient tem-

perature.

High-cycle Maintenance-free Battery

These batteries respond better than standard mainte-

nance-free. Charge acceptance of these batteries may

display characteristics similar to maintenance batteries.

AGM (Absorbed Glass Mat) Maintenance-free Battery

These dry-cell batteries respond better than standard

maintenance-free. If battery state of charge drops to

75% or less, batteries should be recharged to 95% or

higher separately from the engine’s charging system to

avoid damaging charging system components and to

provide best overall performance. Charge acceptance of

these batteries may display characteristics similar to

maintenance batteries.

NOTICE

Hazard Defi nitions

This term indicates special instructions

on installation, operation or mainte-

nance that are important but not

related to personal injury hazards.

NOTICE

Troubleshooting Guide

for N2013 Battery Isolator

Battery Charge Volt and Amp Values

Volt and amp levels fluctuate depending on the battery state

of charge. If batteries are in a state of discharge—as after

extended cranking time to start the engine—system volts

will measure lower than the regulator setpoint after the

engine is restarted and system amps will measure higher.

This is a normal condition for the charging system; the

greater the battery discharge level, the lower the system

volts and the higher the system amps. The volt and amp

readings will change as batteries recover and become fully

charged: system volts will increase to regulator setpoint

and system amps will decrease to low level (depending on

other loads).

Low Amps: Minimum or lowest charging system amp

value required to maintain battery state of charge,

obtained when testing the charging system with a fully

charged battery and no other loads applied. This value

will vary with battery type.

Medium Amps: System amps value which can cause

the battery temperature to rise above adequate charg-

ing temperature within 4-8 hours of charge time. To

prevent battery damage, the charge amps should be

reduced when battery temperature rises. Check battery

manufacturer’s recommendations for proper charge

amp rates.

High Amps: System amps value which can cause

the battery temperature to rise above adequate charg-

ing temperature within 2-3 hours of charge time. To

prevent battery damage, the charge amps should be

reduced when battery temperature rises. Check battery

manufacturer’s recommendations for proper charge

amp rates.

Battery Voltage: Steady-state voltage value as mea-

sured with battery in open circuit with no battery load.

This value relates to battery state of charge.

Charge Voltage: Voltage value obtained when the

charging system is operating. This value will be

higher than battery voltage and must never exceed

the regulator voltage setpoint.

B+ Voltage: Voltage value obtained when measuring

voltage at battery positive terminal or alternator B+

terminal.

Surface Charge: Higher than normal battery voltage

occurring when the battery is disconnected from

battery charger. The surface charge must be removed

to determine true battery voltage and state of charge.

Significant Magnetism: Change in strength or

intensity of a magnetic field present in alternator

rotor shaft when the field coil is energized. The

magnetic field strength when the field coil is energized

should feel stronger than when the field is not ener-

gized.

Voltage Droop or Sag: Normal condition occurring

when the load demand on alternator is greater than

rated alternator output at given rotor shaft RPM.

Advertising