2. DESCRIPTION

Electric Fryers:

These electric units are designed for countertop operation. They are used for producing evenly cooked,

perfectly fried products.

5

3. INSTALLATION

1.

Follow General Installation Instructions on previous page.

Screw legs into the permanently fastened nuts on the four corners of the unit and tighten by

hand. Level the fryer by turning the adjustment screw at the bottom of each leg. Do not slide unit with

legs mounted, lift if necessary to move unit.

These values are nominal ratings. Field wire connections must be capable of withstanding

anticipated surges.

For testing, see the wiring diagrams in this manual for the rated amperages.

NOTE:

!

!

CAUTION: Installing personnel should be guided by National Electrical Code NFPA Number 70-

(Latest Edition), and applicablelocal codes..

4. THERMOSTAT CALIBRATION

Checking Thermostat Calibration:

MAX

MIN

The fryer thermostat is carefully calibrated at the factory so that dial settings match actual frying compound

temperatures. Field re-calibration is seldom necessary unless the unit has been mishandled in transit or

abused. Re-calibration should not be resorted to unless considerable experience with cooking results

definitely proves that the control is not maintaining the temperature to which the dial is set.

1.

To check compound frying temperatures when re-calibrating, use a precision test instrument, or a

good grade mercury thermometer. Fill the tank half way between the

and

marks on the

tank.

2.

Frying compound temperature should be checked at the center of the tank, approximately 1” to

1 1/2” below surface of frying compound.

3.

Turn the dial of the thermostat being checked to the 350°F mark.

4.

Allow temperature to stabilize, or until the thermostat cycles to “OFF” three times after starting

with cold frying compound. With power “ON”, read highest and lowest frying compound

temperature, as thermostat cycles through at least two cycles.Average the reading.

5.

Thermostat should be re-calibrated if temperature reading is not within 10 degrees of the

control knob setting (350°F +/- 15°F). If re-calibration is required, continue with steps 6, 7, 8 and 9.

6.

Remove control knob by grasping outer edge and pulling straight out, without twisting or turning.

7.

Hold thermostat dial shaft “B” (Figure 1) stationary with pliers, and with a screwdriver, turn screw “A”

clockwise to obtain a lower temperature; or counter-clockwise for higher temperature. Each ¼ turn

(90° rotation) of screw “A” represents 18°F.

8.

Replace thermostat control knob.

9.

Recheck thermostat as in Steps 4 and 5 above. If the fat temperature is not within 20 degrees of dial

setting (350°F +/- 20°F), it means that the sensing element is inoperative and the thermostatic

control should be replaced.