7 • troubleshooting – Hunter 27208 Fan/Light Universal User Manual

Page 10

Advertising
background image

44092-01 • 12/15/10 • Hunter Fan Company

10

7 • Troubleshooting

Symptom

Possible Causes

Solution

1.No functions operate.

Main Power not restored.

Replace fuse. Turn ON circuit breaker. Turn ON wall switch.

Fan pull chain not set to High.

Set fan pull chain to High speed.

Light pull chain not set to ON.

Set light kit to ON.

Receiver wiring incorrect.

Verify wiring connections.

Transmitter not programmed to

receiver in fan.

Re-program the remote. Refer to “Programming the Remote,” Page 8.

Battery too weak.

Replace with new, 12-Volt alkaline battery. Refer to “Transmitter Installation”, Section 5.

2.Fan clicks when remote buttons

pushed, but blades do not move.

Fan pull chain not set to High.

Set fan pull chain to High speed.

3.Fan clicks when remote buttons

pushed, but light does not work.

Light pull chain not set to ON.

Pull light chain to turn ON.

4.Operates only at close range.

Signal blocked from reaching

receiver.

Extend antenna into ceiling box, or move it for better reception.

Battery too weak.

Replace with new, 12-Volt alkaline battery. Refer to “Transmitter Installation”, Section 5.

Interference

Re-program the remote to a different frequency by pressing and holding fan speed

buttons 1 & 3 together for 5 seconds. Light on transmitter will blink 3 times. Light will

come on and fan will turn on at low speed to confirm programming is complete.

5.Inconsistent operation.

Signal partially blocked from

reaching receiver.

Extend antenna into ceiling box, or move it for better reception.

RF interference.

Turn OFF wall switch for 5 seconds, then turn back ON.

Continuing RF interference.

Re-program the remote. Refer to “Programming the Remote,” Page 8.

Advertising