I 0568 - 14

10

GB

5.5.1 - Indication of exact correction weight position

It is advisable use this function in the event of correction of the external side using an adhesive weight placed inside
the rim. Remember to thoroughly clean the application areas.
This function allows cancelling approximations in the mounting of counterweights with consequent reduction of the
residual unbalance.

- Press button

from the Measurements screen.

- Pull out the rim distance + diameter gauge in position A, fi gure 5. Approach of the weight to the correction posi-

tion is indicated by a moving coloured arrow [

].

- When a fi xed arrow [

] is reached, rotate the wheel to correction position (FI or FE) and apply the counterweight

by turning the tip of the gauge towards the outside, into the position in which touches the wheel. Compensation is
made for the fact that the weight application position is no longer at 12 o’clock (fi g. 11).

When the acoustic signal is enabled (see

ACOUSTIC SIGNAL

), the reaching of a fi xed arrow [

] is accompanied by

a “beep”.