7 - errors – CEMB USA C29_2 (B) User Manual

Page 15

Advertising
background image

I 0533 -

15

GB

7 - Errors

During machine operation there may be various causes of malfunctioning which, if detected by the microprocessor,
are indicated on the display:

ERRORS CAUSES

CONTROLS

Black

The wheel balancer does not come on.

1. Check proper connection to the mains.

2. Check and if necessary replace the fuses on the power board.

3. Replace the computer board.

Err. 1

No rotation signal.

1. Check belt tautness.

2. Check functioning of the phase generator and, in particular, the

reset signal.

3. Replace the phase generator.

4. Replace the computer board.

Err. 2

Too low speed during measurement.

During the unbalance measurement

revolutions, the wheel speed has fallen to

below 42 rpm.

1. Check that a vehicle wheel has been mounted on the wheel

balancer.

2. Check belt tautness.

3. Check functioning of the phase generator and, in particular, the

reset signal.

4. Replace the computer board.

Err. 3

Too high unbalance.

1. Check the wheel dimension setting.

2. Check the sensor connections.

3. Run the machine calibration function.

4. Mount a wheel with a more or less known unbalance (less than 100

grams) and check the machine response.

5. Replace the computer board.

Err. 4

Rotation in opposite direction.

After pressing [START], the wheel

starts turning in the opposite direction

(anticlockwise).

1. Verify the connection of the UP/DOWN - RESET signals on the

phase generator.

Err. 7 /

Err. 8 /

Err. 9

NOVRAM parameter read error

1. Repeat machine calibration

2. Shut down the machine.

3. Wait for at least ~ 1 min.

4. Restart the machine and check proper functioning.

5. Replace the computer board.

Err. 11

Too high speed error.

The average spinning speed is greater than

240 rpm.

1. Check if there is any damage or dirt on the timing disc.

2. Check functioning of the phase generator and, in particular, the

reset signal.

3. Replace the computer board.

Err. 12

Unbalance measuring cycle error.

1. Verify phase pick-up board function.

2. Verify correct motor operation.

3. Verify belt tautness.

4. Replace the computer board.

Err.13/

Err.14/

Err.15/

Err.16/

Err.17/

Err.18

Unbalance measurement error.

1. Check functioning of the phase generator.

2. Check the sensor connections.

3. Check the machine earthing connection.

4. Mount a wheel with a more or less known unbalance (less than 100

grams) and check the machine response.

5. Replace the computer board.

Err. 24

Distance between the spokes smaller

than 18 degrees.

1. The minimum distance between the spokes where to split the

unbalance must be greater than 18 degrees

2. Repeat the SPLIT function increasing the distance between the

spokes.

Err. 25

Distance between the spokes greater

than 120 degree

1. The minimum distance between the spokes where to split the

unbalance must be smaller than 120 degrees

2. Repeat the SPLIT function increasing the distance between the

spokes.