background image

ALU S :

I 0202 - 21

GB

To display static unbalance, press the

button on the measurement screen (for ALUS static,

the inner side diameter is always considered).
Possible types of correction:

Balancing of steel or light alloy rims with application of clip-on

weights on the rim edges

The STATIC mode is necessary for motorcycle wheels or when it is not

possible to place the counterweights on both sides of the rim.

Balancing of light alloy rims with application of adhesive weights on

the rim shoulders.

Combined balancing: adhesive weight on the outside, clip-on weight

inside


Combined balancing: clip-on weight outside and adhesive

weight inside.


Balancing of alloy rims with hidden application of the adhesive

weight on the outside.

Combined balancing: clip-on weight inside and adhesive hidden

weight outside (Mercedes).

5.5.5 - TO CANCEL STATIC UNBALANCE

This function can be selected from the Setup screen. It serves for optimizing the residual unbalance by
correcting a wheel with standard counterweights in steps of 5 grams (1/4 oz.).
Thanks to this particular function, the position and best correction value are calculated in order to cancel
the static unbalance: the main cause of the vibrations which can be felt inside the car.

5.6

-

STATISTICS

DAILY N° OF RUNS:
Indicates the number of runs performed as from switching on the machine. Such parameter is automatically
reset after switching the machine off.

TOTAL N° OF RUNS:
Indicates the number of runs performed as from
the last resetting of such counter. This parameter
remains memorized also when the machine is
switched off.
The following push buttons are enabled:

: serves for resetting the daily number of

runs

: serves for resetting the total number of

runs. Requires correct setting of a

password.

: for returning to previous screen (MENU)

: for returning to Measurement screen

STATISTICS

Daily N° of runs

Total n° of runs

Resetting daily n° of runs

Resetting total n° of runs

Cancel

Advertising