2 - handling and hoisting, 3 - commissioning, 4 - specification – CEMB USA K10 (D) User Manual

Page 4: 1 - anchoring, 2 - electrical connection

Advertising
background image

I 0215 - 4

GB

NOTE: DO NOT HOIST THE MACHINE USING DIFFERENT GRIPS

(See “Correct head disassembly” - paragraph:

GENERAL SAFETY REGULATIONS

)

1.4 - SPECIFICATION

Weight (excluding adapter)

~ 80Kg.

Single-phase power supply

115 / 230 V 50/60 Hz

Protection class

IP 54

Max power consumption

800 W

Balancing speed

< 100 min

-1

Cycle time for average wheel (14 kg)

6-8 seconds

Max.resolution of measurement

1 gram

Position resolution

± 1.4 °

Average noise

< 70dB (A)

Rim-machine distance

0 - 265 mm

Rim width setting range

1.5” ÷ 20” or 40 ÷ 510 mm

Diameter setting range

10” ÷ 26” or 265 ÷ 665 mm

2 - HANDLING AND HOISTING

Fig. 2

Fig. 2a

3 - COMMISSIONING

3.1 - ANCHORING

The machine can operate on any flat non resilient floor.

Make sure that the machine rests solely on the three support points provided (fig.2a).

3.2 - ELECTRICAL CONNECTION

The machine is supplied with a single phase mains cable plus earth (ground).

The supply voltage (and mains frequency) is given on the machine nameplate. It cannot be changed.

Connection to the mains should always be made by expert personnel.

The machine should not be started up without proper earthing.

Connection to the mains should be through a slow acting safety switch rated at 3 A (230V) or 8 A (115V).

See enclosed layout.

Advertising