Composition

Integrated transmitter body in stainless steel AISI 316L material

Power supply

24 Vdc (10 to 35 Vdc) current loop 4 to 20 mA (2 wires)

maximum load, as per figure 2

External connections

connector 2 poles MIL-C-5015 (conductors max section 2,5 mm²)

Environmental use field

- 50°C to + 120°C

IP 65 EN 60529/10.91 standard

Measure type

Omnidirectional Seismic (absolute vibrations)

Dynamic field

± 18 g

Transversal sensitivity

< 5 %

Linearity

± 2% - 75 Hz

Dynamic performances

±3% / 10Hz-1kHz (See figure 1)

-3db / 1.5Hz – 2.5kHz

Insulation

 10

8

 between signal and container

Application axis

any

Standard machine connection thread

M8x1,25

¼’’ – 18NPT

¼’’ – 28UNF

Maintenance

nothing

Electrical connections

bipolar shielded cable, conductors typical section 2x1mm²

Possible arrangements to the order

measuring field

fastening

Mounting torque

5÷10 N-m

Technical characteristics

Advertising