This pictorial guide shows how to test popular types of

lead acid batteries with the new GOLD-PLUS.

“They say a picture speaks a thousand words

but if all else fails read the manual”

ACT Meters Ltd

The Old Smithy

Church Road

Rainford

Merseyside

WA11 8HD

United Kingdom

Tel: +44(0)1744 886660

Fax: +44(0)1744 886661

USA Freecall: 1-877-712-2278

Email: [email protected]

Web: www.actmeters.com

GOLD-PLUS Intelligent Battery Tester

Operating Manual

R2.21

Battery Testing Tips

1:

Don’t buy flat batteries!

Because lead acid batteries normally self-discharge about 3% per

month, it is very important to decipher the date of manufacture

code stamped on the battery. This is essential for inventory

rotation and to avoid stocking old discharged batteries. If you

cannot decipher the date code, contact your supplier or battery

to ship from far eastern manufacturers, before going through your

distributor to you.

2:

Check the voltage.

To avoid potential battery failure problems, it is essential to check

the voltage level in new lead acid batteries to ensure that they

have been sufficiently charged by the manufacturer before leaving

the factory. Any new out-of-the-box battery with less than 6.1V for

6V and 12.2V for 12V must be recharged overnight and retested

before use. Generally, a new battery will have above 6.2V for 6V

and 12.4V for 12V batteries.

3:

Constant charge voltage.

Lead acid batteries require a constant voltage, irrespective of Ah

capacity size in order to charge efficiently. The optimum charge

voltage required is 2.3vpc (volts per cell) which is 6.9V for a three

cell 6V battery and 13.8V for a six cell 12V battery. The voltage

tolerance is 2.2vpc min and 2.4vpc max. The time taken to fully

charge is dependent on battery Ah size.

4:

Battery surface charge.

When testing batteries just taken off charge, it is important that the

excess surface charge voltage (13.8 - 14.4V) is removed in order

to measure battery Ah capacity accurately. When ‘ANALYSING

BATT’ is displayed, the GOLD-PLUS applies a pulse load to

remove excess surface charge. Ah accuracy is assured below

13.3VDC. If necessary, repeat test to remove surface voltage.

5:

Batteries hate heat!

For maximum life and performance, a lead acid battery should be

maintained at between 20 - 25C (68 - 77F). At significantly higher

or lower temperatures the Ah capacity available could vary by up

to 50%. Be aware that lead acid batteries hate heat. The hotter

the battery, the shorter its life!

6:

Equal capacity.

To ensure maximum efficiency and to avoid charging problems,

where two or more lead acid batteries are connected in parallel or

series, make sure that they are the same make, type and Ah size

and after testing have about equal Ah capacity available.

7:

When to recharge or replace?

To ensure efficiency, battery manufactures recommend to

recharge or replace the battery when its available Ah capacity falls

below 65%. However, if your requirements recommend a higher

or lower percentage, then recharge or replace accordingly.

Any questions? Please give us a call on +44 (0)1744 886660 or

email [email protected]

GOLD-PLUS Specifications

Operating Voltage:

5V - 15V DC Max

Reverse Polarity:

Red LED indication

Battery Types:

Standby SLA, Cyclic GEL &

Car FLOODED Battery Sizes:

6v 1.2Ah - 12Ah

Ah Capacity Test:

Simulated full 20 hour load

test (C20hr) performed in just

20 seconds. Repeat Ah test

takes just 5 seconds

Applied Pulse Load:

6A for 1.2Ah - 9.9Ah batteries

batteries

Ah Calibration:

Calibrated at 0 (zero) position

to new, fully charged, popular

brand Standby SLA batteries

at 20 - 25C (68 - 77F). Ah

control (00 - 99) for Cyclic

GEL and Car FLOODED

batteries according to Ah size

Battery Table:

Recharge or replace battery

when ‘FLAT BATTERY’ or Ah

capacity falls below 65%

Display Type:

Back-lit 13 digit LCD

Flat Battery Warning:

6v <5.25VDC, 12v <12.0VDC

Repeat Test Operation:

Can perform repeat tests or

continuously as required

DCV Accuracy:

+/- 2% of displayed reading

Ah Accuracy:

+/- 10% fully charge premium

brand C20hr rated SLA

batteries at 20 - 25C (68-77F)

Case Construction:

High impact ABS

Moisture Protection:

IP54

Size:

H210 x W110 x D41mm

Weight: 0.6kg

In The Box:

GOLD-PLUS Intelligent

Battery Tester, ACT-GPTL Test

Leads, ACT-430N Soft Carry

Case, 25xBTL (Battery Tested

Labels) Operating Instructions

and Declaration of Conformity

Warranty:

1 Year from date of Invoice

Address:

ACT Meters Ltd

The Old Smithy

Church Road

Rainford

Merseyside

Post Code:

WA11 8HD

Country:

United Kingdom

Phone:

+44(0)1744 886660

Fax:

+44(0)1744 886661

USA Freecall:

1-877-712-2278

Email:

[email protected]

Web:

www.actmeters.com

12v 1.2Ah - 1

50Ah

manufacturer. Be aware that new batteries can take many months

18A for 10Ah - 150Ah

[email protected]

Advertising