5

CONNECTIONS

The Hydra uses a bi-directional 2-wire RS-485 data bus to communicate to the
slave devices. The device at each end of the network must be terminated. An
8-DIP switch on the rear of the unit is used to set the termination. Switch No.
8 is the terminal switch. When set to ON, the device is terminated. When set
to OFF, it will be un-terminated.

Figure 2: Regcom Rear Panel

RJ45
PIN 4 (+)
PIN 5 (-)

RJ45
PIN 4

(+)

PIN 5

(-)

Table 3: RS-485 Network

Data Cable Wiring

(120 Ohm impedance terminated)

PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8

RS-485 (+)
RS-485 (-)

Table 2: RJ45 Pin-Out

PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
PIN 9

RX (RS-232)
TX (RS-232)

GROUND

Table 1: DB-9 Pin-Out