The AC/DC mA Current Clamp is a transducer which will allow your
multimeter to measure low electrical and/or electronic current up to
60 Amperes AC/DC, with a frequency response up to 20kHz. When
measuring current with this clamp, there is no need to break a circuit or
to affect the isolation.
The extended measurement jaws allow performing measurements in
a narrow space. When measuring DC current, a simple operating push
button is designed for zero adjustment. The clamp adapter is applicable
to leakage detection or monitoring.

How to take DCmA Alarm Current Readings

1. Plug clamp leads into multimeter COM and DC Voltage sockets and

switch on

2. Switch multimeter to DC mV range
3. Switch clamp to 1mV/10mA range
4. Hold clamp steadily over the wire
5. Press clamp ZERO button until meter reads zero
6. Close clamp jaw over the negative DC wire to PIR/KEYPAD/LIM.

Example: 1.5mV=15mA, 15.0mV=150mA

7. For DC Amps, switch clamp to 10mV/100mA range, press ZERO and

close jaw over negative DC wire. Example: 15.0mV=1.50Amps

CA60

mA Current Clamp

Operation

www.actmeters.com