It is strongly recommended resetting all of the default values of your

Pulse LE unit before setting up your shows and events. To do so,

press the

[EXIT/MENU]

button and select Control in the menu by

rotating the corresponding knob. Then press the

[ENTER]

button to

enter the Control sub-menu. Select Default Values by rotating the

scroll knob, and press the

[ENTER]

button to enter your choice to

restart your

Pulse LE with its factory settings. This operation should

take approximatly 30 seconds.

Analog Way engineers have developped a handy, user friendly way

of identifying machine status on the front panel, via the use of color

codes on the buttons of the machine. All new Analog Way machines

use the same codes, for quick recognition of the status of any device

of the range, at any given time.

For the

Pulse LE, button color codes are as follow:

- Sources on the Main output are indicated in red when active.

- Sources on the Preview output are indicated in green when active.

- Buttons in the layer section turn red or green, depending on

whether the selected layer is active in respectively the Main or

Preview window.

- Menu buttons are indicated in green.

- Selecting a button with an available source or function will cause

that button to blink green on the preview, or red once it is on the

Main output.

-

[TAKE]

button reacts as follows:

If take function is available, the button will appear in green.

When the take function is active, it will light up red.

4-3. WORKING WITH THE OPS200

Reseting default values

PLS300 color codes

#1 = Source, Layer or Window is on Main

#2 = Freeze enable

#1 = Source or Layer is on Preview

#2 = Function available for modification

#3 = Current output on Matrix Mode

Active Layer or Source for modification on Main

Active Layer or Source for modification on Preview

Solid red:

Solid green:

Blinking red:

Blinking green: