QUICK START GUIDE

Thank you for choosing

Analog Way

and the RK-350. By following these simple steps, you should be able

to setup and use your powerful remote Control Keypad within minutes. Discover the RK-350 extensive

capabilities and intuitive interface while configuring your first show, and unleash your creativity for a new

experience in show and event management by

Analog Way

.

• 1 x RK-350 (RK-350)

• 1 x Power supply cord

• 1 x DB9 (M/F) cable

• 1 x Carrying case

• 1 x Quick Start guide*

* The Quick Start guide is also available on

www.analogway.com

WHAT’S IN THE BOX

RK-350 SETTINGS

• The RK-350 automatically detects the right versions of

the product to control. Connect the DB9 cable supplied

or an Ethernet crossover cable using the same protocol

as the connected unit.

• To control the following Seamless Switchers:

Control Mode

Seamless

Mixer

Seamless

Matrix

Quadravision

EKS550

x

x

x

QMX150

x

SMX250

x

QVU150

x

PLS350

x

x

SPX450

x

x

Navigation Menu:

To access the RK-350 menu, press the EXIT/MENU button

in the control section. To highlight items in the menu which

will appear on the VFD screen, turn the scroll knob left or

right to the desired menu item. When you have reached

the desired menu item, press the ENTER button in the

control section to access that menu function.

Pressing the ENTER button when a selection has been made

sets the value to that selection in the RK-350 memory.

When all settings have been made, press the EXIT/MENU

button to exit sub-menus and return to the main menu.

IMPORTANT:

simply selecting a menu item will not set

it to that value. Be sure to press the ENTER button when

parametering the menu items.

Once you have connected your RK-350 to your switcher,

configure the connection settings on both devices.

For a serial connection, select RS232 from the RS232/LAN

menu on both devices. (In CONTROL menu)

For a LAN connection, select LAN from the RS232/LAN menu

on both devices (In CONTROL menu), and configure each

device with a unique IP in the LAN setup > RK-350 address

menu. The default IP on the RK-350 is

192.168.2.141

.

Next, enter the IP of the device you wish to control in the

Lan Setup > Device address menu.

Once your settings are correct, the RK-350 will begin

to synchronize with the device, and you will be ready to

begin. (Wait a minute).
Button color usage:

Solid red:

#1 = Source is on the Program output

#2 = Freeze enable

#3 = Stand-by button

#4 = Mute enable

Solid green:

Solid orange:

Blinking red:

Blinking green:

#1 = Source is on Preview

#2 = Function available for modification

Unlocked sources / Shifted keys

Layer/source selected or is currently active

on the Program output

Layer/source selected or is not currently

active on the Program output