Tape

⅓ of width

2 times pipe

circumference

18˝

– 1 –

– 2 –

– 3 –

– 4 –

Measure a piece of Barrier-Bac

Vapor Retarder membrane 18 inch-

es in width and twice (two times)

the circumference of the pipe.

Roll the measured piece of mem-

brane in a roll form approximately

the size of pipe.

Flatten sized roll and make vertical

cuts to approximately one-third of

the width and two inches apart.

Open boot and wrap snugly around

pipe, spreading cuts around base so

strips lay horizontal to base.
Tape around pipe circumference at

top of boot, down side seam of boot

and all two inch horizontal strips.

Cover all seams of membrane with

seaming tape.

All penetrations must be sealed with the Barrier-Bac and BB20T Seam

Tape. For round pipe or posts, please seal penetrations with Pipe Boot.