HCW4

MAGNETIC INCREMENTAL MODULAR SENSORS, HCW4 RANGE

OUTPUT ELECTRONIC / POWER SUPPLY

2G2 electronic (100kHz)

Supply : 5Vdc

10%

Cons. without load : 40mA max

Current per channel : 40mA max

0 max (Is=20mA) : V

ol

= 0,5Vdc

1 min (Is=20mA) : V

oh

= 2,5Vdc

PG5 electronic(100kHz)

Supply : 5 to 30Vdc

Cons. without load : 40mA max

Current per channel : 40mA max

0 max (Is=20mA) : V

ol

= 0,5Vdc

1min (Is=20mA) : V

oh

= Vcc-2,5Vdc

Protection against short circuits and inversion of polarity for the electronic PG5.


STANDARD CONNECTION

-

+

A

B

0

A/

B/

0/

Ground

G3

PVC cable

8 wires

8230/020

WH

white

BN

brown

GN

green

YE

yellow

GY

grey

PK

pink

BU

blue

RD

red

Main

shield

GP

PUR cable

12 wires

8230/050

WH white +

WH/GN

white/green

BU blue +

BN/GN

brown / green

GY

grey

BN

brown

RD

red

PK

pink

GN

green

BK

black

General

shielding

ORDERING REFERENCE

(Contact the factory for special versions , ex: stainless steel version, connections…)

Mechanics

Supply

Output stage

Signals

Resolution

Connection

Connection

orientation

HCW4:

Incremental

encoder

00:

Modular

2G2:

5Vdc

TTL / RS422 output


PG5:

5 to 30Vdc

Push-pull output

(TTL / RS422 available if

encoder supply is 5Vdc)

9:

A, A/,

B, B/,

0, 0/

1024 :

max

G3 :

PVC cable

8 wires


GP:

PUR cable

12 wires


R020 :

Radial

cable 2m

Ex: HCW4_

00 //

PG5

9 //

01024 //

G3

R020

AVAILABLE RESOLUTIONS


32 64 128 256 1024


Made in FRANCE

Changes possible without further notice 100520

BEI Sensors SAS
Espace Européen de l’Entreprise
9, rue de Copenhague
B.P. 70044 Schiltigheim
F 67013 Strasbourg Cedex

Tél

: +33 (0)3 88 20 80 80

Fax

: +33 (0)3 88 20 87 87

Mail

:

[email protected]

Web

: www.beisensors.com

Advertising