BEI Sensors LT25 Linear Cable Transducer User Manual

Lt25 linear cable position transducer

Advertising
background image

Tel: 805-968-0782 /800-350-2727 | Fax: 805-968-3154 /800-960-2726 | 7230 Hollister Ave., Goleta, CA 93117-2807

www.beisensors.com

Specification No. 02115-001 Rev.08-11

Model LT25 linear cable position transducer provides digital position and
speed information in a rugged, easy-to-install package. Simply connect the

cable to your moving equipment and secure the base to a fixed object. No
need to worry about shaft misalignment. The sturdy measuring cable is

made of nylon coated stainless steel for ultimate strength, with a
measurement range up to 125 inches. This unit is ideal for wet, dirty or

outdoor environments and applications where your measuring range travels

over harsh environments.

Mechanical Specifications

Enclosure: Anodized Aluminum and glass filled

polycarbonate (transducer), die cast aluminum

(encoder)

Measuring Range: 0 to 125 Inches

Measuring Cable: Nylon Coated Stainless

Steel (.034 Dia.)

Maximum Velocity: 80” per second

Measuring Cable Tension: 24.8 ± 30% oz

Rotational Sensitivity: 12” ± .020 in/rev

Maximum Retraction Acceleration: 10 G

Weight: Approximately 3.3 lbs (max)

BEI Sensors

Electrical Specifications

Supply Voltage: 5-28 VDC available
Voltage/Output:
25V/V: 5-28 VDC in, Vout = Vin
Current Requirements: 100 mA typical + output
load, 250 mA max
Protection Level: Reverse, over voltage and
output short circuit
Code: Incremental
Output Format: 2 Channels in quadrature, with ½
cycle index gated with negative B channel
Resolution: Pulses per Inch (see Table 1)
Output Termination: M18 Connector (See Table 2)


LT25
Linear Cable Position Transducer


Environmental Specifications

Enclosure Rating: IP66
Temperature: Operating, 0° to 70°C; storage (non-
operating), -25° to 90°C. Consult factory for
extended temperature ratings.
Shock: 50 g’s for 11 msec duration
Vibration: 5 to 2000 Hz @ 20 g’s
Humidity: 98% RH without condensation

LT25 Linear Cable Position Transducer Ordering Options For assistance, call 800-350-2727

Use this diagram, working from left to right, to construct your model number.

Example: LT25D-100-ABZC-28V/V-SM18

LT25D

S

Pulses Per Inch:
10, 25, 50, 100, 250, 500
(
See Resolutions Table 1)

Outputs
ABZC = Dual Channels with
Index and Complements

ABZC

Special Features:
Consult Factory

SM18

Output Termination:
S
M18 = Side Termination,
MS3102R18-1P

Voltage/Output
28V/V = 5-28Vin/out

28V/V

Mechanical life of cable: 1.3 million cycles (min)
(1 cycle = 1 extension + 1 retraction)

EN 55011 and EN 61000-6-2

CENELEC EEX ia IIC T4*

U.S. Standards Class I, Group A, B, C & D;
Class I Group E,F & G

Canadian Standards

Class I, Zone 0, Group IIC

The LT25 is available with the following certifications:

* For ordering information on the LT25 with Ex certification, contact factory.

Advertising