CANopen Industrial Datasheet

Version 130305

INCLI NO MET E R

CA NOPE N

Technical Data

Electrical Data

Model

INC 5

INC 15

INC 30

Measuring range

+/- 5°

+/- 15°

+/- 30°

Resolution

0.001°

0,001°

0,005°

Accuracy (T = 0 °C .. +55 °C)

0,01°

0,01°

0,02°

Inclination angle in x and y (1)

+/-15°

+/-40°

+/-60°

Damping period 0° -> 5°

typical 1s 10%, 2s 1%, 3s 0,1%

Interface

Transceiver according ISO 11898,

galvanically isolated by opto-couplers

Transmission rate

max. 1 MBaud

Device addressing

Adjustable by rotary switches in connection cap

Supply voltage (2)

10

– 30 V DC (absolute limits)

Current consumption

max. 230 mA with 10 V DC, max. 100 mA with 24 V DC

Power consumption

max. 2.2 Watts

EMC

Emitted interference: EN 61000-6-4

Noise immunity:

EN 61000-6-3

Electrical lifetime

> 10

5

h

(1) Supply voltage is applied.

(2) Inclinometers should be connected only to subsequent electronics whose power supplies comply with

EN 50178 (protective low voltage)

Mechanical Data

Housing

Aluminum

Lifetime

> 10

5

h

Shock

A=30g; t= 11ms, halfsine (EN 60068-2-27)

Vibration

10 to 150 Hz, 2,5 mm amplitude, 5g const. Acceleration,

1 Octave /Minute (EN 60068-2-6)

Weight (standard version)

350 g

Environmental Conditions

Operating temperature

-40°C......+85°C

Storage temperature

-40°C......+85°C

Humidity

98 % (without liquid state)

Protection class

IP 67 (connected) (EN 60529)