Intrinsic Safety Barrier

Specification No.: 02125-004

These commodities, technology or software if exported from the United States must be in accordance

with the Bureau of Industry, and Security, Export Administration regulations. Diversion contrary to U.S.

law is prohibited.

This Intrinsic Safety Barrier Module is the perfect complement

to BEI’s Intrinsically Safe Encoders and, when used together,

constitutes a completely engineered solution for encoder

operation in Class I and Class II, Division 1 (Zone 0) Hazardous

Environments. This single barrier provides both power and

signal isolation for an incremental encoder with differential

quadrature outputs and an index. This all-in-one approach

saves the cost, inconvenience and system design time needed

when using separate power and signal barriers. This barrier

is galvanically isolated which eliminates the added cost of

maintaining a high integrity earth ground. With differential line

driver outputs, this barrier can be used to carry signals reliably

up to 500 feet with a bandwidth of up to 250 kHz. It is designed

around a standard DIN Rail mounting (Type EN 50022, 35 mm

X 7.5 mm) for easy installation in standard enclosures. A length

of DIN rail is supplied with each module. The module simply

snaps directly to the DIN rail and is ready to use.
The Intrinsic Safety Barrier Module is certified to be installed in

Class I, Div. 2 (Zone 2) areas.
When properly connected, differential data signals have an

inherent immunity to noise since it is rejected as common

mode. However if a connection between the encoder and the

barrier is broken or improperly terminated it can act as an

antenna and still create a signal. An open wire detection (ISD)

option is available on BEI’s Intrinsically Safe Barriers (28V/V

and 28V/5 only). In the event that the data line is cut or not

properly connected the ISD option can detect a change in the

impedance of the connection and cause the output data on

both legs of the differential signal to go low. This creates an

erroneous logic state that can be used by the operator to halt or

modify a process.

Intrinsic Safety Barrier Ordering Options

for assistance, call 800.350.2727

Use this diagram, working from left to right to construct your model number (example: EM-DR1-IS-5-RTB-28V/V)

This Intrinsic Safety Barrier has certifications

to be used as an associated apparatus for

intrinsically safe encoders installed in the

following hazardous locations:

US Class I, Group A,B,C,D;
Class II, Groups E,F,G; Class III

Canadian Class I, Zone 0, Group IIC

II 3 (1) G Ex nA [ia Ga] IIC T4 Gc

Ex nA [ia Ga] IIC T4 Gc

EN 55011 and 61000-6-2

EM

DR1

TYPE:

EM = Electronic Module, DIN Rail

mount

FUNCTION

IS= Intrinsically Safe

ISD = Intrinsically Safe with

Open Wire Detection (available

with 28V/V or 28V/5 supply

voltage/output)

OUTPUT TERMINATION:

RTB =

RemoveTerminal

Block

VOLTAGE/OUTPUT:

28V/V = 12-28 VDC, Vout = Vin
28V/5 = 12-28 VDC, Vout = 5 volts
28V/OC = 12-28 VDC, Vout = Open Coll.

IS

RTB

PACKAGE STYLE:

DR1 = 114.5 mm x 99mm x

22.5 mm

5

OUTPUT VOLTAGE TO

ENCODER

5=5 VDC

Advertising