PERFORMANCE

Static Pressure (inches of w.g.)

HVI CFM

Fan Speed

Power

Air Flow - CFM

0

0.2

0.4

0.6

0.8

1.0

@ .2 SP

RPM

Watts

AIF4X, AIK14X, AIK14XF

122

100

78

55

-

-

100

Yes

2900

19

AIK14XL

122

100

78

55

-

-

100

No

2900

19

AIK24Y

167

150

133

113

88

-

150

No

2900

80

AIK16X

214

190

162

132

99

-

190

Yes

2850

61

AIF6Y, AIK26Y, AIK26YF

263

230

198

167

136

106

230

Yes

2700

71

AIK26YL

263

230

198

167

136

106

230

No

2700

71

AIF8X

408

360

308

259

213

173

360

Yes

2750

122

AIF10X

649

600

553

506

454

403

600

No

2850

240

SPECIFICATIONS

EXHAUST FANS

INLINE

INLINE EXHAUST FANS

• Motors

Enclosed 2 pole, life time lubrication, ball bearing motor. Suitable
for continuous operation. Maximum air temperature 140° F.

• Blower Wheel

Backward inclined, balanced polymeric single inlet blower wheel.

• Electrical Connections

1/2

" electrical knockouts provided with internal terminal block.

• Unit Mounting

Metal fan mounting bracket included with the unit

• UPC Codes

AIF4X: 0-83162-24001-9

AIK14X: 0-83162-31091-0

AIK14XL: 0-83162-31111-5

AIK14XF: 0-83162-31142-9

AIK24Y: 0-83162-31101-6

AIK16X: 0-83162-31092-7

AIF6Y: 0-83162-24002-6

AIK26Y: 0-83162-31102-3

AIK26YL: 0-83162-31121-4

AIK26YF: 0-83162-31143-6

AIF8X: 0-83162-24011-8

AIF10X: 0-83162-24012-5

Canada: 110 Glidden Road
Brampton, Ontario L6T 2J3
Tel: (905) 456-2033
Fax: (905) 456-1015

U.S.: 820 Lincoln Drive
West Chester, Pennsylvania 19380-4466
Tel: (877)-304-3785
Fax: (610) 696-8048

Rev. B 1-07

Specifications subject to change without notice.

C

US

PROJECT

LOCATION

CONTRACTOR

ARCHITECT

ENGINEER

SUBMITTED BY

DATE

FAN

MODEL

CFM

IN

RPM

WATTS

AMPS

SONES

QTY

OPTIONAL EQUIPMENT

NUMBER NUMBER

W.G.

& REMARKS

Model

VOLTS

Hz

AMPS

DUCT

AIF4X, AIK14X,

AIK14XL, AIK14XF

115

60

.18

4"

AIK24Y

115

60

.72

4"

AIK16X

115

60

.53

6"

AIF6Y, AIK26Y

AIK26YL, AIK26YF

115

60

.67

6"

AIF8X

115

60

1.11

8"

AIF10X

115

60

2.40

10"

Model

A1*

A2

C

D

E

F

AIF4X, AIK14X,

AIK14XL, AIK14XF

4"

5"

9

1/2

"

6

1/8

"

7/8

"

7/8

"

AIK24Y

4"

5"

9

1/2

"

6

1/8

"

7/8

"

7/8

"

AIK16X

6"

6

1/4

"

11

3/4

"

5

7/8

"

1"

7/8

"

AIF6Y, AIK26Y,

AIK26YL, AIK26YF

6"

6

1/4

"

11

3/4

"

5

7/8

"

1"

7/8

"

AIF8X

8"

10"

13

1/4

"

6

1/4

"

1

1/2

"

1

1/2

"

AIF10X

-

10"

13

1/4

"

6

1/4

"

1

1/2

"

-

Please note: The Home Ventilation Institute (HVI) does not currently have a sound test standard for remote mounted fans.
As a result sound levels (sones) are not listed. In most cases, a remote fan will be quieter than one mounted within the living area.

E

C

F

D

A1

A2

Advertising