Switchers – Altinex MX2436RM User Manual

Page 12

Advertising
background image

SWITCHERS

11

6. [#Bn] - Beep ON/OFF

# = Switcher module ID number (default is 0)

n = ON/OFF switch

n = 1 (Turns switcher Beep ON)

n = 0 (Turns switcher Beep OFF)

This command activates or deactivates the
beeping sound when a key is pressed on the
switcher module.

Example:

Sending the command [8B1] set the beeper ON
in the connected Switcher module with ID
number eight.

7. [OASn] - Auto Switch

n = ON/OFF switch

n = 1 (Turns auto switcher ON)

n = 0 (Turns auto switcher OFF)

The [OASn] command sets the switcher
module to the ON position to auto detect the
incoming audio or video signals or OFF to
operate it manually or with a PC software.

Example:

Sending the [OAS1] command will set the auto
switch feature to the ON position, which will
automatically detect the incoming video signal.

8. [0I#] - Change Identification Number

0 = Zero

# = New Switcher module ID number (no.
from 1 to 9).

This command sets a unique ID number to each
MX2436RM Switcher module. A total of 9 unit
ID’s can be assigned.

Example:

Sending the command [0I8] will reset the active
Switcher module with the new ID number eight.
In addition, by default the switcher still has ID
number zero.

9. [#CA n1 n2 ] - Audio Gain Control Save

Settings

# = Switch number (default is 0; no. from 1

to 9).

n1 = Audio input number (no. from 0 to 6).

n2 = Audio Gain (Hexadecimal no. from 1 to
F).

The [#CA n1 n2 ] command will save the

volume settings for a specified audio input.

Example:

After the [8CA6F] command has been
executed, switcher module 8 and Audio Input
number 6 will have a maximum volume of F (0
= OFF, default is 8 or normal volume).

10. [#CA n1 n2 ] – Video Equalization Save

Settings

# = Switch number (default is 0; no. from

1 to 9).

n1 = Video input number (no. from 0 to 6)

n2 = Video equalization. (Hexadecimal no.
from 1 to F).

This command saves the settings of equalized
video signals to compensate for cable lengths
from the video source to the switcher.

Example:

When sending the [8CA58] command, Switcher
module 8 and Video Input number 5 will have a
medium equalization range of 8 (0 = OFF).

11. [#VR] - Firmware Version

This command displays the firmware revision
number that is installed into the microprocessor.

# = Switch number (default is 0; no. from 1 to
9).

Example:

When sending the [8VR] command the system
will return the version number 8R1.0. When
sending the [0VR] command the system will
return the version number 8R1.0.

Advertising