Aiphone KB-SWS User Manual

Page 2

Advertising
background image

3A2 3A1 2A2 2A1 1A2 1A1

3A2 3A1 2A2 2A1 1A2 1A1

INSTALLATION DIAGRAM:

KB-MV2

Rear View

U
P

KB-SWM & KB-SWS

Rear View

Installation:
-

Mount the KB-SWM and KB-SWS into the GF-2F or GF-3F mounting bracket.

-

Plug the KB-MV2 / KB-MV3 connector cable into the KB-SWM. If any KB-SWS sub-modules are used, plug the
KB-MV2 / KB-MV3 connector cable into the closest one, then plug its blue and yellow 10-pin connector into the next
switch module, daisy-chaining them together. Plug the last KB-SWS connector into the KB-SWM master switch module.

-

Connect the black and white wire from the KB-MV2 / KB-MV3 connector cable to the SKK-620 power leads (cut spade
lug connectors). The white wire connects to +6VDC (black w/white stripe), and the black wire to -6VDC (solid black).

-

Connect wires from KB-3MRD’s to corresponding terminals on the KB-SWM / KB-SWS. (1A1, 1A2 = upper button,
2A1, 2A2 = middle button, 3A1, 3A2 = lower button)

-

Install completed entry panel into either the GF-2B / GF-3B (semi-flush mount) or GF-nHB (surface mount) as required.

-

Use Aiphone series wire 871802. Wire must be 18AWG solid, non-shielded, PE insulation.

Initialization:
-

The entrance panel must be powered on prior to powering the
tenant stations.

-

After the entrance and tenant stations are powered on, initialize
the system by calling each tenant from each entry panel.

KB-SWM

KB-SWS

NOT USED

WHITE

BLACK

To + 6VDC

To - 6VDC

To KB-3MRD

To KB-3MRD

To KB-3MRD

To KB-3MRD

To KB-3MRD

To KB-3MRD

GF-2F

(frame & bracket)

GF-3F

(frame & bracket)

KB-SWM & KB-SWS’s

mounted in bracket