Dynasonics PFP-600 User Manual

Page 13

Advertising
background image

units = 5-8, and 10
pipe ID range is 102 mm. - 1524 mm.


To set high alarm (RELAY-2), press “HIGH ALARM” key. The

µP display will show

“ALARM HIGH”. Use the “SCROLL” keys to increase or decrease value. The default

value is 20.00. When finished, press “ENTER” key to exit.

units = 1-4
high alarm range is 0.00” - 60.00”

units =5-8
high alarm range is 0.00 - 6.08 MPS

units =9
high alarm range is 0.00” - 60.00”

units = 10
high alarm range is 0.00 cm. - 152.00 cm.


To set low alarm (RELAY-1), press “LOW ALARM” key. The

µP display will show

“ALARM LOW”. Use the “SCROLL” keys to increase or decrease value. Default value

is 00.00. When finished, press “ENTER” key to exit.


units = 1-4 (flow)
low alarm range is 0.00 - 20.00 FPS

units = 5-8 (flow)
low alarm range is 0.00 - 6.08 MPS


units = 9 (level)
low alarm range is 0.00” - 60.00”

units = 10 (level)
low alarm range is 0.00 cm. - 152.00 cm.

Totalizer operation display with or without multiplier

units = 2 - 4
totalizer range is 0 - 99999999 GALS (GALLONS)

units = 6 - 8
totalizer range is 0 - 99999999 LTRS (liters)

11