Configurable HMI Panel

Installation Guide and User Manual

Page 11 / 16


Byte sequence set LED status

Host request

START_HOST CODE_LEDi LEDByte1 LEDByte2

END

IDENTIFIER

Keyboard response

START_CONTROLLER

CODE_LEDi LEDByte1

LEDByte2

END

IDENTIFIER

Byte sequence get LED status

Host request

START_HOST CODE_LEDo

END

IDENTIFIER

Keyboard response

START_CONTROLLER

CODE_LEDo LEDByte1 LEDByte2

END

IDENTIFIER

Messages of keyboard controller

Error in frame

START_CONTROLLER

ERROR

mirror received bytes

END

IDENTIFIER

Unknown command

START_CONTROLLER

CODE UNKNOWN

mirror command

END

IDENTIFIER

Data frame keyboard

Byte sequence key codes START_CONTROLLER

Modifier Byte

Key code byte1

Key code byte2

Key code byte3

END IDENTIFIER

Table 4 - Data frames serial communication