Aiphone C-123LW User Manual

Page 3

Advertising
background image

1

E

E

-

1

L
L

+

-

RY-AC

BELL

SKK-620B

IMPORTANT: Connect wires

before applying power.

C-123LW Supplement

Pg. 3

WIRING DIAGRAM: LEM-1DL System with External Signaling using RY-AC Relay

+

MODIFICATION INSTRUCTIONS:
C-ML/A with Door Release contact Modifi ed to Normally Closed (for Magnetic Lock)

Normally Open Dry

Contact to door

strike and power

Component Module*
If a DAK-2S is not available, install components as shown below.
Capacitor: 25V, 15-33ufd Non-polarized
Diode: 1N4148

Output of RY-AC (Yellow
wires) provide a momentary
dry contact closure while
the call button on the door
station is being pressed.

12V DC power

supply

NOTE: Negative of
power supplies must be
tied together.

C-ML/A

Component

Module*

C-D

White

Red

Black

Power source

for bell

To 1 of C-D and
WHITE wire of RY-AC

To 1 of C-ML/A

Magnetic locks require Normally
Closed contacts, keeping power
applied to the magnet to keep the door
locked, and breaking power to release
the door. These instructions explain
how to change the contact in the
C-ML/A to Normally Closed.

1. Remove back chassis of C-ML/A
and move the PC-754 board aside.
Black door release switch will be
visible.
2. On the switch, move* the wire from
the NO contact (middle position) to
the NC contact (top position).
*Desoldering and resoldering is
required.
3. This modifi cation will change the
door release button’s function to
Normally Closed, to be used with
magnetic lock device.
4. Switch contact rating is 1A at 50V
AC.

+

-

60H-2

A

8

THA1

547

Door release

switch

COM

NO

NC

C-ML/A Rear View with PC board removed.

Advertising