Troubleshooting guide – Sotera 800 Series (825, 850) User Manual

Page 7

Advertising
background image

7

TROUBLESHOOTING GUIDE

PROBLEM POSSIBLE CAUSE SOLUTION NOTES

Meter won't turn on

•Dead batteries

•Replace batteries.

Seal to electronic chamber

•Damaged or contaminated •Replace electronics module

is broken if display label is

electronics module

& gaskets.

removed or punctured.

Flashing decimal •Current total has rolled

•Reset display to zero by pressing

Meter will continue to

over

button 2.

operate normally.

Flashing or

•Low batteries

•Replace batteries.

Use alkaline batteries.

dim display
Leaking fluid at

•Need thread sealant

•Add Teflon pipe tape to joint.

inlet/outlet port

•Cross-threaded port

•Replace body

Fluid flows; meter •Meter disk sticking

•Clean out meter chamber.

won't count

•Damaged driver

•Repair or replace chamber assembly.

or magnet
•Meter failure

•Repair or replace meter.

Meter reads high

•Air in system

•Prime system, fix suction leak at pump. Meter will count air.

•Wrong calibration factor

•Use a higher calibration factor. See

Chemical formulations

1-Step procedure

sometimes change.

•See "Check Meter" in Appendix-A

Meter reads low by

•Wrong calibration factor

•Use a lower calibration factor.

Chemical formulations

10% or less

•See 1-Step procedure.

sometimes change. Temperature
also affects accuracy.

Meter reads low by

•Meter chamber is worn

•Recalibrate meter with water. See

more than 10%

•Chamber is partially

Appendix-B. See "Check Meter" in

plugged

Appendix-A.
•Clean chamber

•Damaged or very worn

•Replace chamber and recalibrate

chamber

meter.

Meter is not

•Air in system

•Prime system, fix suction leak at pump.

consistent

•Particulates in fluid

•Put screen in front of meter.

40 mesh minimum.

•Meter has worn or

•Clean chamber

damaged chamber

•Replace chamber.

Err0

•Calibration error

•Recalibrate meter with more accurate

Indicates fluid calibration is

container.

out of acceptable window.

•Damaged chamber

•Replace chamber.

Volumetric container may

be off, there may be air in
the system, or the meter
chamber may be damaged.

Err1

•Damaged electronics

•Repair or replace electronics.

Contact factory.

•Software fault

•Press 2 then recalibrate meter

Err2

•Bad eeprom

•Replace electronics

Meter still functions, but all
data will be lost if batteries
are removed.