Mains Sup ply (rack units)

The 3U rack has a fused, voltage selector IEC mains input connector.

The 5U rack has a free standing AC supply with a fused, voltage selector IEC mains input connector
and connects to the rack via a connector and a 1.5 meter cable.

The mains switch on the rear panel of the 3U rack unit is non-illuminating.

The CH (chassis) and 0V are linked internally.

DC Power Sup ply In di ca tors (rack units)

The red LED on the front panel of both 3U and 5U rack units indicates +24V power healthy when
illuminated.

The green LED on the front panel of both 3U and 5U rack units indicates +48V power healthy when
illuminated.

Phan tom Power

Phantom power can be supplied to each module by pressing the phantom power switch on the front
panel of the 3U or 5U rack. The LED in the switch will illuminate confirming that phantom power is
supplied.

Out put Level Con trol

Each channel has an independent Output Level Control. The control is post-input, post-EQ and
pre-output. This control can reduce the level at the output.

When the Output Control is fully clockwise the output gain is unity. The output is 20dB down with
the control in the mid-position.