REMOTE CONTROL


Remote Control:
When using a slide potentiometer as a remote control, wire with High (T) to the voltage terminal (‘V’), Wiper (W) to the
control terminal ("C"), and Low (B) to the ground terminal (‘

d

’). When using a rotary potentiometer, wire with High (CW) to the voltage

terminal ("V"), Wiper (W) to the control terminal ("C"), and Low (CCW) to the ground terminal ("

d

"). Potentiometers should be linear taper,

of any value from 5k ohms to 50k ohms, and may be wired up to 2000 feet from the mixer. Cable should be 2-conductor with shield. A
remote level control wall-plate, model RP-L1, is available. If an on/off switch is utilized, "ON" position should connect the voltage terminal
(‘V") to the control terminal ("C"). Different wiring techniques, using both a potentiometer and a switch, can provide either level and mute
functions or adjustable muting attenuation.

NOTE: The rear panel Remote Enable switch must be depressed for remote controls to function (see Enable Switches on page 3).