REAR PANEL

Input
These plug-in barrier strips provide the balanced line-level inputs to the channels. For balanced
connection, wire high (+), low (-), and ground ( ). For unbalanced connection, wire high (+) and
ground to both ( ) & (-).

NOTE: When using a pair of channels in ‘bridged’ mode (see Bridge below), input signal must be
connected to the odd numbered channel.

Level
These screw-driver adjustable controls determine the level of input signals allowed into the
channels. Level provides a gain range from ‘off’ (min.) to ‘unity’ (max.). The Level control is
factory set for -24dB of gain, which will produce maximum output power with input signal peaks of
+24dBu. For best performance, first adjust the source signals for optimum (maximum) levels, then
adjust the MCA Series Level controls for the desired volume.

Signal / Peak Indicators
These 2-color LEDs indicate the signal level for each channel. When an LED is green, that channel
has signal (above -30dB). When an LED is red, that channel signal is clipping (max. power).

CAUTION: Signal levels should be adjusted to avoid clipping. Clipping can cause severe distortion,
over-temperature conditions, and even loudspeaker damage.

NOTE: Signal / Peak indicators will turn off during Temp / Fault condition (see Temp / Fault
Indicators on pg. 5).

FU

SE

FU

SE

O

2

1

1

2

outputs

level

signal / peak

signal / peak

level

t

u

p

n

i

t

u

p

n

i

4

3

3

4

outputs

level

signal / peak

signal / peak

level

t

u

p

n

i

t

u

p

n

i

6

5

Class 2 Wiring

5

6

outputs

level

signal / peak

signal / peak

level

t

u

p

n

i

t

u

p

n

i

8

7

7

8

outputs

level

CAUTION:

Risk of fire -

replace fuse only

with same type

115V: F 10 A H 250 V

230V: T 4 A L 250 V

signal / peak

signal / peak

level

input

input

MCA 8050

HPF

HPF

OFF

OFF

OFF

BRIDGE

HPF

HPF

OFF

OFF

OFF

BRIDGE

HPF

HPF

OFF

OFF

OFF

BRIDGE

HPF

HPF

OFF

OFF

OFF

BRIDGE

CAUTION

RISK OF ELECTRICAL SHOCK.

DO NOT OPEN.

52SJ

UL

R

LISTED

C

US

BIAMP SYSTEMS

Designed in Oregon, U.S.A.

Assembled in India

~

115/230VAC 50-60Hz 900 Watts

115

FU

SE

FU

SE

O

level

signal / peak

signal / peak

level

level

signal / peak

signal / peak

level

level

signal / peak

signal / peak

level

level

signal / peak

signal / peak

level

HPF

HPF

OFF

OFF

OFF

HPF

HPF

OFF

OFF

OFF

HPF

HPF

OFF

OFF

OFF

HPF

HPF

OFF

OFF

OFF

BRIDGE

BRIDGE

BRIDGE

BRIDGE

1

2

outputs

3

4

outputs

5

6

outputs

7

8

outputs

2

1

t

u

p

n

i

t

u

p

n

i

4

3

t

u

p

n

i

t

u

p

n

i

6

5

t

u

p

n

i

t

u

p

n

i

8

7

t

u

p

n

i

t

u

p

n

i

MCA 8150

CAUTION

RISK OF ELECTRICAL SHOCK.

DO NOT OPEN.

Class 2 Wiring

BIAMP SYSTEMS

Designed in Oregon, U.S.A.

Assembled in India

CAUTION:

Risk of fire -

replace fuse only

with same type

115V: F 15 A H 250 V

230V: T 6.3 A L 250 V

52SJ

UL

R

LISTED

C

US

~

115/230VAC 50-60Hz 1800 Watts

115

MCA 8050 Rear Panel

MCA 8150 Rear Panel

Advertising
This manual is related to the following products: