Networked Paging Station-1 - System Connections


Networked Paging Station-1 units are connected to an AudiaFLEX system via Ethernet switches, forming a dedicated CobraNet

®

network.

Multiple switches may be used to extend the CobraNet network. In systems designs that include multiple AudiaFLEX units, all Networked
Paging Station-1 units and all AudiaFLEX units should be connected together on a common CobraNet network.


In the system design, each Networked Paging Station-1 unit is associated by name with a Networked Paging Station block (Station ID).
Multiple Networked Paging Station-1 units may be assigned the same name (Station ID), and will assume identical page routing schemes
(soft-buttons) as those programmed in the corresponding Networked Paging Station-1 block. However, other settings (such as Net Config,
Password, Button Mode, Page Timeout, Mic Gain, and Button Order) may be customized per unit during setup.