RP-S4

Remote Panel (Switches)


RP-S4: The RP-S4 is a remote control panel, which consists of four double-
pole*/double-throw switches mounted on a grey ‘decorator’ style cover plate,
with a single-gang ‘cut-in’ style PVC electrical back-box and four pre-wired
pigtails. The RP-S4 may be used to provide remote control switching as
specified for the following BIAMP products:

products functions
801 Mic/Line Mixer . . . . . . . . . Main Output (mute)
601 Mic/Line Mixer . . . . . . . . . Main Output (mute)
301 Mic/Line Mixer . . . . . . . . . Main Output (mute)
CMA Series Mixer/Amplifiers . . . . Main Output (mute)
IWA250 In-Wall Mixer/Amplifier . . . Inputs/Outputs (mute)
VSX41 Video Switcher . . . . . . . Inputs 1~4 (selection)
VRAM Automatic Mixer . . . . . . . programmable logic inputs
MSP11 Signal Processor . . . . . . programmable logic inputs
MSP22e Signal Processor . . . . . programmable logic inputs
SPM723 Stereo Preamp/Mixer . . . programmable logic inputs
Voltage Control Box

. . . . . . . . Various Products

Audia (programmable)
Nexia (programmable)
Logic Box . . . . . . . . . . . . . Various Products
Audia (programmable)
Nexia (programmable)

The RP-S4 includes four pre-wired pigtails for ease of installation. Each pigtail
consists of three 22-gauge wires, which are color-coded for wiring as follows:

White . . . . Up (released - out)
Red . . . . Center (wiper)
Green . . . Down (depressed - in)


See product manuals for remote control applications and wiring specifics.
Soldered connections with heat-shrink, or properly sized crimp connectors, are
recommended. See last page for back-box installation & block diagrams.
* NOTE: Factory wiring (across both switch poles) provides single-pole
operation. This may be modified if double-pole switch operation is desired.

RP-S4

1

2

3

4










Momentary Switch Operation:
From the factory, RP-S4 switches provide a
‘push-on/push-off’ (latching) type of operation. For some applications
(especially when used with the RIK Remote Interface Kit), the switch operation
must be ‘momentary’ (non-latching). The RP-S4 switches each include a small
removable metal jumper strap which provides the latching function. For
momentary switch operation, remove the jumper strap from each switch using
needle-nose pliers. One end of the jumper is under the switch spring, which
may need to be gently moved out of the way. If latching operation should again
become necessary, replace the jumper straps by reversing this process.