7

½”, and that will be above the upper bearing. Do not overfill, an air gap of 10-15%

must be maintained for heat expansion.

PUMP INSTALLATION


KZN-F Series pumps have been evaluated for use with water or water based solutions.
Please contact the manufacturer for additional information.

Risk of electric shock. KZN-F Series pump models do not come

with electric plug connectors. To reduce the risk of electric shock, be certain that it is
connected only to a properly grounded, grounding-type receptacle or control panels.

Lifting:

Attach a rope or lifting chain (not included) to the handle (or lifting rings) on the top of
the pump.

Do not lift the pump by the power cable or discharge hose/piping.

Proper lifting equipment (rope/chain) must be used.

POSITIONING THE PUMP


BJM Pumps
, KZN-F Series pumps are designed to operate fully or partially submerged.
Do not run the pump dry. Refer to data sheet for minimum submersion depth for your
particular model. Data sheets can be obtained online at

HU

www.bjmpumps.com

UH

or by

calling BJM Pumps, LLC at 860-399-5937. As a general rule, KZN Series top discharge
pumps can pump down to a level above the suction screen. Pumping lower than the
screen will permit air to enter the pump and cavitate, lose prime or become air bound.

Do not run pumps dry.

Pump liquid should not exceed a maximum temperature of 200°F (93°C).

Never place the pump on loose or soft ground. The pump may sink, preventing

water from reaching the impeller. Place on a solid surface or suspend the pump
with a lifting rope/chain. The KZN-F Series pumps are provided with a suction
strainer to prevent large solids from clogging the impeller. Any spherical solids
which pass through the strainer should pass through the pump.

For maximum pumping capacity, use the proper size non-collapsible hose or rigid

piping. A check valve may be installed after the discharge to prevent back flow
when the pump is shut off.