Installation and operation manual – Brooks Instrument QMBM User Manual

Page 18

Advertising
background image

QmB Series IP40, IP66, IP66XP

Section 1 Introduction

1-6

Installation and Operation Manual

X-CM-QmB-eng

Part Number: 541B029AAG

June, 2011

Physical Specifications

Materials of Construction:

Process Wetted: 316L, 316L VAR, High Alloy Ferritic Stainless and 17-7PH
Optional: Hastelloy sensor tube.
Process Seals:
Elastomer Seal: Viton

®

fluoroelastomers, Buna, Kalrez

®

or EPDM

Metal Seal: Stainless Steel and Nickel

Housing:

IP40: Polyurethane painted Aluminum
IP66: Polyurethane painted Aluminum
IP66XP: Aluminum

Inlet Filter:

Tube Size 2 Controller: 1 micron or 10 micron inlet filter recommended
Tube Size 3 or 4: 10, 20, 30 & 40 micron filters available

Weight:

Housing: IP40: 1.6 kg or 3.5 Lbs.
Housing: IP66: 1.9 kg or 4.2 Lbs.
Housing: IP66XP: 24 kg or 52 Lbs.

Moisture Content:

Purged to exhaust dew point less than -40°C (-40°F) prior to shipment
to remove calibration liquid, to prevent process contamination.
Then vacuum bagged at ambient room conditions.

Process Fitting Options:

1/16", 1/8", 1/4" or 6mm tube compression, VCR, VCO or NPT(F), 3.2 mm
UPG, Down Port ANSI/ISA 76.00.02 (See Model Code).

Electrical Connections:

IP40: 15 pin D-Type connector. (See Figure 3).
IP66: Unpluggable Terminal Block 28-16 Awg.
IP66XP: ¾" NPT wiring access to IP40 Device with 15 pin D-Type connector.

Dimensions:

See Figures 1-1 through 1-7

Functional Specifications
Output Signals

(13)

:

• 4-20 mA or 0-5 Vdc active outputs represent mass flow or volume flow

(4)

.

• And simultaneously available 4-20 mA or 0-5 Vdc active output, represents
on-line density or temperature information.
• Alarm output, max. voltage 30 Vdc, max. current 100 mA

Input Signals

(13)

:

• Command (setpoint) that drives the control valve, either 4-20 mA or
0-5 Vdc input signals.

• Valve Override Function:
Left floating/unconnected - instrument controls flow at setpoint
Connected to signal at or above 5.0 Volts -valve is forced open
Connected to signal at or below 0.0 Volts -valve is forced closed

Advertising