Model 1358 – Brooks Instrument 1358 User Manual

Page 8

Advertising
background image

Installation and Operation Manual

X-VA-1358-eng

Part Number: 541B041AAG

September, 2012

1-2

Section 1 Introduction

Model 1358

Scales
Type (Standard): Fused on meter tube
Length: 75 mm, nominal
Graduations:

Standard: direct read on tube in gpm water or scfm air.
Optional: special direct read decal on tube. Consult factory for
available ranges. Direct read on metal scale plate mounted beside
tube.

Capacities and Pressure Drops
Refer to Table 1-1

Standard accuracy:
±10% of full scale from 100% to 10% of scale reading.

Repeatability
0.5% full scale

Rangeability
Ten to one

Table 1-1 Capacities

Maximum Flow Rate

Pressure Drop

Pressure Drop

Water

Without Valve

With Valve

(gpm)

Inches W.C.

Inches W. C.

Float

0.8

12.6

13.6

8-RV-8

1.5

22.2

27.0

8-RJ-10

2.5

61.0

85.2

8-RJ-23

3.5

88.7

121.0

8-RJ-30

5.0

172

238.0

8-RJ-39

Pressure Drop

Pressure Drop

Air

Without Valve

With Valve

(scfm)

Inches W.C.

Inches W.C.

Float

3.4

14.34

15.5

8-RV-8

6.0

25.34

30.8

8-RJ-10

12.0

69.34

97.3

8-RJ-23

15.0

101.34

138.3

8-RJ-30

NOTE: All air flows are at 14.7 psia and 70°F.

Connections
Standard: Horizontal female 3/8" NPT threaded adaptors.

Dimensions
See Figure 1-1

Materials of Construction:

Metering Tube
Borosilicate glass

Advertising