Burkert Type 0212 User Manual

Burkert Accessories for water

Advertising
background image

Operating Instructions

Type 0211/0212

Design:
2-way solenoid valve, direct acting, normally closed (Circuit
function A) or normally open (Circuit function B).

Seal Materials and Fluids handled:
See Table.

Fluid and Ambient Temperature:
For Hazardous Locations Div. 1 (T4 rated)
Max. Ambient Temperature

104 °F (40 °C)

Max. Fluid Temperature

194 °F (90 °C)

The UL-listed valve for Hazardous Locations is suitable for
the fluids air, inert gas, water and gasoline.

For Hazardous Locations Div. 1 (T6 rated)
Max. Ambient Temperature

104 °F (40 °C)

Max. Fluid Temperature

140 °F (60 °C)

For Hazardous Locations Div. 2 and Ordinary Locations:
See Table.

Pressure Range:
Maximum inlet pressure see label on valve.

Installation:
Before installing valve ensure that piping etc. is free of foreign
matter (metal fillings, seal materials, welding scale etc.). In-
stallation as required but preferably with coil uppermost. Instal-
lation in this position tends to prevent foreign matter remaining
in core tube (increased life). Do not put any loads on coil unit.

Type 0211: PTFE tape is recommended for sealing ports. Arrow
on valve body indicates flow direction. Mounting is accomplished
by means of four M4 x 8 mm tapped holes located on the valve
underside.

Type 0212: Outlet port is coded on side of body. For common
pressure, align "A" marking on valve and manifold. To remove
valve from manifold loosen only the two unsealed screws.
Manifolds can be connected togehter with nipples.

Marking (example):

Circuit function
A

=

Normally Closed

B

=

Normally Open

Seal Material
EPDM

=

EPDM

NBR

=

NBR

FKM

=

FKM

EA

=

PTFE seat and EPDM O-ring

EF

=

PTFE seat and FKM O-ring

NN

=

Neoprene

Body Material
BR

=

Brass

SS

=

Stainless Steel

NI

=

Nickel Plated Brass

PL

=

Polyamide Plastic

Maximum Pressure

Voltage / Frequency / Power Consumption

Recorder No.

Approvals
The valve is either approved as

General Purpose valve for Hazardous Locations

Class I, Division 1, Group A, B, C, D
Class II, Division 1, Group E, F, G
Class III, Division 1 and 2
Operating Temperature T 4

or

General Purpose valve for Hazardous Locations

Class I, Division 1, Group A, B, C, D
Class II, Division 1, Group E, F, G
Class III, Division 1 and 2
Operating Temperature T 6

or

FM approved as

Nonincendive for Hazardous Locations
Class I, Division 2, Group A, B, C, D
Class II, Division 2, Group F, G
Class III, Division 1 and 2
Operating Temperature T 4

UL listed for Ordinary locations
CSA approved for Ordinary locations

See label on the valve.

Operating Instructions 0605/08_EU-EN_00893132

Seal Materials Seat / O-ring

Fluid

Tempera-
tures [° F]

Buna „N‰

Ethylene
Propylene

FKM

PTFE/
Ethylene
Propyl.

PTFE/
FKM

Neoprene

Air

Fluid T.

Ambient

+14 to +194
+14 to +130

-40 to +266
+14 to +130

+14 to +266
+14 to +130

+14 to +266
+14 to +130

+14 to +266
+14 to +130

Water

Fluid T.

Ambient

+32 to +194
+32 to +130

+32 to +212
+32 to +130

+32 to +212
+32 to +130

+32 to +212
+32 to +130

+32 to +212
+32 to +130

Neutral Gas

Fluid T.

Ambient

+14 to +194
+14 to +130

-40 to +266
+14 to +130

+14 to +266
+14 to +130

+14 to +266
+14 to +130

+14 to +266
+14 to +130

Light oil

Fluid T.

Ambient

+14 to +194
+14 to +130

+14 to +266
+14 to +130

+14 to +266
+14 to +130

LP-gas

Fluid T.

Ambient

+14 to +140
+14 to +130

+14 to +140
+14 to +130

+14 to +140
+14 to +130

Refrigerants

Fluid T.

Ambient

+14 to +194
+14 to +130

Voltage 12V or 24V

UL / UR valid with

class 2 power supply only

Advertising