Operating instructions type 0255

Advertising
background image

Operating Instructions

Type 0255

Recorder No.

Voltage / Frequency / Power Consumption

Maximum Pressure

Marking (example):

Body Material
BR

=

Brass

SS

=

Stainless Steel

Seal Material
EPDM

=

EPDM

NBR

=

NBR

FKM

=

FKM

EA

=

PTFE seat and EPDM O-ring

EF

=

PTFE seat and FKM O-ring

CF

=

FFKM seat and FKM O-ring

Circuit function
A =

Normally Closed

Design:
2-way solenoid valve, direct acting, normally closed (Circuit
function A).

Seal Materials and Fluids handled:
See Table.

Fluid and Ambient Temperature:
See Table.

Pressure Range:
Maximum inlet pressure see label on valve.

Installation:
Before installing valve ensure that piping etc. is free of foreign
matter (metal fillings, seal materials, welding scale etc.). Instal-
lation as required but preferably with coil uppermost. Installati-
on in this position tends to prevent foreign matter remaining in
core tube (increased life). Do not put any loads on coil unit.

Type 0255: PTFE tape is recommended for sealing ports.
Arrow on valve body indicates flow direction. Mounting is
accomplished by 2 holes 6.5 mm thru valve body.

Operating Instructions 0605/08_EU-EN_00893149

Seal Materials

Fluid

Tempera-
tures [° F]

Buna „N‰

Ethylene
Propylene

FKM

Steel

PTFE

FFKM

Air

Fluid T.

Ambient

+ 14 to + 194
+ 14 to + 130

- 40 to + 266
+ 14 to + 130

+ 14 to + 266
+ 14 to + 130

- 40 to + 356
+ 14 to + 130

- 40 to + 356
+ 14 to + 130

+ 14 to + 266
+ 14 to + 130

Water

Fluid T.

Ambient

+ 50 to + 194
+ 32 to + 130

+ 50 to + 212
+ 32 to + 130

+ 50 to + 212
+ 32 to + 130

+ 50 to + 212
+ 32 to + 130

+ 50 to + 212
+ 32 to + 130

+ 50 to + 212
+ 32 to + 130

Neutral Gas

Fluid T.

Ambient

+ 14 to + 194
+ 14 to + 130

- 40 to + 266
+ 14 to + 130

+ 14 to + 266
+ 14 to + 130

- 40 to + 356

+ 14 to + 130

- 40 to + 356
+ 14 to + 130

+ 14 to + 266
+ 14 to + 130

Light oil

Fluid T.

Ambient

+ 50 to + 194
+ 14 to + 130

+ 50 to + 194
+ 14 to + 130

+ 50 to + 194
+ 14 to + 130

+ 50 to + 194
+ 14 to + 130

+ 50 to + 194
+ 14 to + 130

LP-gas

Fluid T.

Ambient

+ 14 to + 140
+ 14 to + 130

+ 14 to + 140
+ 14 to + 130

+ 14 to + 140
+ 14 to + 130

+ 14 to + 140
+ 14 to + 130

+ 14 to + 140
+ 14 to + 130

Steam

Fluid T.

Ambient

+ 212 to + 266
+ 14 to + 130

+ 212 to + 266
+ 14 to + 130

+ 212 to + 356
+ 14 to + 130

+ 212 to + 356
+ 14 to + 130

+ 212 to + 266
+ 14 to + 130

Voltage 12V or 24V

UL / UR valid with

class 2 power supply only