Burkert Type 0280 User Manual

Operating instructions type 0280

Advertising
background image

Operating Instructions

Type 0280

Recorder No.

Voltage / Frequency / Power Consumption

Maximum Pressure

Marking (example):

Body Material
BR

=

Brass

SS

=

Stainless Steel

NI

=

Nickel Plated Brass

PL

=

Polyamide Plastic

Seal Material
EPDM

=

EPDM

NBR

=

NBR

FKM

=

FKM

Circuit function
A

=

Normally Closed

B

=

Normally Open

Operating Instructions 0605/08_EU-EN_00893133

Approvals
The valve is either approved as

General Purpose valve for Hazardous Locations

Class I, Division 1, Group A, B, C, D
Class II, Division 1, Group E, F, G
Class III, Division 1 and 2
Operating Temperature T 4

or

FM approved as

Nonincendive for Hazardous Locations
Class I, Division 2, Group A, B, C, D
Class II, Division 2, Group F, G
Class III, Division 1 and 2
Operating Temperature T 4A

or

UL listed for Ordinary locations

or

CSA approved for Ordinary locations

See label on the valve.

Design:
2-way solenoid valve, internally piloted, normally closed
(Circuit function A) or normally open (Circuit function B).

Seal Materials and Fluids handled:
See Table.

Fluid and Ambient Temperature:
For Hazardous Locations Div. 1 (T4 rated)
Max. Ambient Temperature

104 °F (40 °C)

Max. Fluid Temperature

194 °F (90 °C)

For Hazardous Locations Div. 2 and Ordinary Locations:
See Table.

Pressure Range:
Minimum pressure differential between and outlet port is 7 PSI.
Maximum inlet pressure see label on valve.

Installation:
Before installing valve ensure that piping etc. is free of foreign
matter (metal fillings, sealing materials, welding scale etc.).
PTFE tape is recommended for sealing ports. Arrow on valve
body gives flow direction. Installation as required but
preferably with coil uppermost. Installation in this position
tends to prevent foreign matter remaining in pilot valve
(increased life). A strainer upstream of valve, protects
against effects of foreign matter. Do not put any loads on coil
unit. Pipework should be supported such that valve body is
not under strain. Do not allow a pipe-end or sealing material
to block the pilot bore within the valve outlet. Inlet and outlet
of valve must be fullbore and pipework unrestricted.

Seal Materials Seat/O-ring

Fluid

Temperatures [° F]

Buna „N‰

Ethylene
Propylene

FKM

Air

Fluid T.

Ambient

+ 14 to + 194
+ 14 to + 130

- 40 to + 194
+ 14 to + 130

+ 14 to + 194
+ 14 to + 130

Water

Fluid T.

Ambient

+ 32 to + 194
+ 32 to + 130

+ 32 to + 194
+ 32 to + 130

+ 32 to + 194
+ 32 to + 130

Neutral Gas

Fluid T.

Ambient

+ 14 to + 194
+ 14 to + 130

- 40 to + 194
+ 14 to + 130

+ 14 to + 194
+ 14 to + 130

Light oil

Fluid T.

Ambient

+ 14 to + 194
+ 14 to + 130

+ 14 to + 194
+ 14 to + 130

LP-gas

Fluid T.

Ambient

+ 14 to + 140
+ 14 to + 130

+ 14 to + 140
+ 14 to + 130

Voltage 12V or 24V

UL / UR valid with

class 2 power supply only

Advertising