5technical data – Burkert Type 0287 User Manual

Page 3

Advertising
background image

5

4.2 Block assembly

The following drawing shows in an example the components which belong
to a block and the place where the accessories can be used.

1

9

8

7

6

2

3

5

4

Pos.

Description

Pos.

Description

1

2 Pull rods

6

Partition wall with O-ring

2

Dummy plate or connection

without Quad ring

7

SV module with or without

adapter

1)

or T-module with

Quad ring

3

SV module with or without

adapter

1)

or T-module

2)

with

Quad ring

8

Dummy plate or connection

with Quad ring

4

Additional connection

9

2 mounting brackets

5

SV module or T-module with

Quad ring

1)

The adapter allows:

- an injecting device to be connected for taking samples

- a sensor to be installed for measuring certain physical or chemical values of

the medium

2)

T-module: Feed module with G1/2“ connection, others on request

english

6

5

Technical daTa

5.1 Operating conditions

The following values are indicated on the type label:
• Voltage (Tolerance ± 10 %) / Current type
• Coil power consumption (active power in W - at operating temp.)
• Pressure range
• Body material: Glass fiber reinforced polyamide,

connections: Brass (MS)

• Sealing material: FKM, EPDM, NBR
• Function of the valve: Collectors or distributors can be mixed

on the block

Circuit function 2/2-way valve:

A (NC)

B (NO)

Protection class:

IP65 in accordance with DIN EN 60529 / IEC
60529 with cable plug, e.g. Bürkert Type 2508

5.2 application conditions

Ambient temperature:

max. +55 °C

Permitted medium temperature and permitted media depending on
sealing material:

Sealing

material

Medium

temperature

Permitted media

FKM

0 ... +70 °C

Diesel and heating oil without additives,
water with additives

EPDM

0 ... +70 °C

Oil and grease-free liquids, cold and
hot water

NBR

0 ... +70 °C

Water

Operating duration: Unless otherwise indicated on the type label,

the solenoid system is suitable for continuous
operation.

For models with a high-power coil a maximum of
6 switching operations per minute are possible.
This applies to devices with power rating
80/6 W.

english

7

Important information for functional reliability during continuous
operation: If standstill for a long period at least 1-2 activations
per day are recommended.

Service life:

High switching frequency and high pressures

reduce the service life

5.3 conformity

In accordance with the EC Declaration of conformity, Type 0287 is com-
pliant with the EC Directives.

5.4 standards

The applied standards, which verify conformity with the EC Directives,
can be found on the EC-Type Examination Certificate and / or the EC
Declaration of Conformity.

5.5 Type label

Type

Circuit

function

Orifice

Sealing material

Body material

Id. Number

Manufacturer code

Voltage, Frequency,

Power consumption

Connection thread, Operating

pressure

0287 A 13,0 NBR MS

Made in Germany

00017317

W17MG

24 V 50-60 Hz 5W

Verteiler

G1/2 P

N 0.5

- 10 bar

Function of the valve

english

Type 0287

Advertising