Burkert Type 0407 User Manual

Operating instructions type 0407

Advertising
background image

Operating Instructions

Type 0407

Design:

2-way solenoid valve, internally piloted, normally closed

(Circuit function A).

Seal Materials and Fluids handled:

See Table1.

Fluid and Ambient Temperature:

See Table 1.

Pressure Range:

Maximum inlet pressure see label on valve.

A pressure differential between inlet port and outlet port is not

required.

Installation:

Before installing valve ensure that piping etc. is free of foreign

matter (metal fillings, seal material, welding scale etc.). PTFE

tape is recommended for sealing ports. Arrow on valve body

gives flow direction. Installation as required but preferable

with coil uppermost. Installation in this position tends to

prevent foreign matter remaining in pilot valve (increased

life). A strainer upstream of valve, protects against effects of

foreign matter. Do not put any loads on coil unit. Pipework

should be supported such that valve body is not under strain.

Do not allow a pipe-end or sealing material to block the pilot

bore within the valve outlet. Inlet and outlet of valve must be

fullbore and pipework unrestricted.

Marking (example):

Body Material

BR

= Brass

Seal Material

EPDM = EPDM

FKM = FKM

EG

= PTFE Seat and Graphite seal

Circuit Function

A = Normally Closed

Recorder No.

Voltage / Frequency / Power Consumption

Maximum Pressure

Operating Instructions 1212/09_EU-EN_00893147

Table 1

Seal materials

Fluid

Tempera-

tures [°F]

Ethylene (A)

Propylene

PTFE (G)

Air

Fluid T.

Ambient

+ 32 to + 275

+ 14 to + 130

+ 32 to + 356

+ 14 to + 130

Water

Fluid T.

Ambient

+ 50 to + 212

+ 32 to + 130

+ 32 to + 212

+ 32 to + 130

Neutral

gas

Fluid T.

Ambient

+ 32 to + 275

+ 14 to + 130

+ 32 to + 356

+ 32 to + 130

Light oil

Fluid T.

Ambient

+ 50 to + 194

+ 14 to + 130

+ 50 to + 194

+ 14 to + 130

LP-gas

Fluid T.

Ambient

+ 32 to + 140

+ 14 to + 130

+ 32 to + 140

+ 14 to + 130

Steam

Fluid T.

Ambient

+ 212 to + 275

+ 14 to + 130

+ 212 to + 356

+ 14 to + 130

Voltage 12V or 24V

UL / UR valid with

class 2 power supply only