Electrical installation requirements, Warning, Danger – Alliance Laundry Systems PHM1397C User Manual

Page 41

Advertising
background image

© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT

Specifications and Dimensions

39

F8112101

Electrical Installation Requirements

IMPORTANT: Electrical ratings are subject to
change. Refer to serial decal for electrical ratings
information specific to your machine.

Electrical connections are made at the rear of the
machine. The machine must be connected to the
proper electrical supply shown on the identification
plate attached to the side of the control module.

IMPORTANT: Alliance Laundry Systems
warranty does not cover components that fail as a
result of improper input voltage.

The AC inverter drive requires a clean power supply
free from voltage spikes and surges. A voltage monitor
should be used to check incoming power. The
customer’s local power company may provide such a
monitor.

If input voltage measures above 230V for a 200V
drive or above 460 for a 400V drive, ask the power
company to lower the voltage. As an alternative, a
step-down transformer kit is available from the
distributor. Voltages above 240 and 480 require
additional measures. Contact the distributor or the
manufacturer for assistance.

This machine must be installed, adjusted,
and serviced by qualified electrical
maintenance personnel familiar with the
construction and operation of this type of
machinery. They must also be familiar
with the potential hazards involved.
Failure to observe this warning may result
in personal injury and/or equipment
damage, and may void the warranty.

SW004

WARNING

Dangerous voltages are present in the
electrical control box(es) and at the motor
terminals. Only qualified personnel
familiar with electrical test procedures,
test equipment, and safety precautions
should attempt adjustments and
troubleshooting. Disconnect power from
the machine before removing the control
box cover, and before attempting any
service procedures.

SW005

WARNING

Ensure that a ground wire from a proven
earth ground is connected to the ground
lug near the input power block on this
machine. Without proper grounding,
personal injury from electric shock could
occur and machine malfunctions may be
evident.

SW008

WARNING

Never touch terminals or components of
the AC inverter drive unless power is
disconnected and the “CHARGE”
indicator LED is off. The AC inverter drive
retains potentially deadly voltage for some
time after the power is disconnected.
There are no user-serviceable parts inside
the AC inverter drive. Tampering with the
drive will void the warranty.

SW009

WARNING

When controlling the AC inverter drive
with a parameter unit, the machine’s
computer and its safety features are
bypassed. This would allow the basket to
rotate at high speeds with the door open.
When using a parameter unit to control the
AC inverter drive, a large sign should be
placed on the front of the machine
warning people of the imminent danger.

SW003

DANGER

This machine must be protected by a
circuit breaker. DO NOT USE FUSES!

W691

WARNING

Advertising