Repairs

10.2.3 inspection intervals

Check diaphragm for wear after maximum 10

5

switching cycles.

Muddy and abrasive media require correspondingly shorter
inspection intervals!

10.2.4 service life of the diaphragm

The service life of the diaphragm depends on the following factors:

• Diaphragm material

• Medium temperature

• Medium

• Actuator size

• Medium pressure

• Control pressure for CFB and CFI

protecting the diaphragm

For CFA match the actuator size (actuator force) to the medium
pressure to be actuated. If required, select the actuator with
reduced spring force EC04.

For CFB and CFI try and select the control pressure not higher
than is required to actuate the medium pressure.

10.2.5 cleaning

Commercially available cleaning agents can be used to clean the outside.

note!

avoid causing damage with cleaning agents.

▶ Before cleaning, check that the cleaning agents are compatible

with the body materials and seals.

11

repairs

11.1 safety instructions

Danger!

risk of injury from high pressure in the equipment!

▶ Before loosening the lines and valves, turn off the pressure and

vent the lines.

risk of injury due to electrical shock!

▶ Before reaching into the system

, switch off the power supply

and secure to prevent reactivation!

▶ Observe applicable accident prevention and safety regulations

for electrical equipment!

Warning!

risk of injury from improper maintenance!

▶ Installation may be carried out by authorized technicians only

and with the appropriate tools.

▶ Observe the tightening torques.

▶ On completion of the work check valve for leaks and function.
risk of injury from unintentional activation of the system and
an uncontrolled restart!

▶ Secure system from unintentional activation.

▶ Following maintenance, ensure a controlled restart.