Burkert Type 6013 User Manual

Page 10

Advertising
background image

10

Technical data

6.5.2. Safety data

Group:

II C

Category:

2 G

Ignition protection type:

Ex ia

Temperature class:

T5 or T6

Max. permitted input voltage (U

i

):

35 V

Max. permitted input current (I

i

):

0.9 A

Max. permitted input power (P

i

):

1.1 W (AC10 - 5)
2.1 W (AC10 -6)

Inductance (L

i

):

~ 0

Capacity (C

i

):

~ 0

The maximum permitted voltages and the associated short-
circuit currents can be found in Table A1 in the standard EN
60079-11 for the corresponding gas group.

Value pairs for the ignition protection type Ex ia II C (example):

Voltage value [V] = U

i

15

18

20

22

Current value [A] = I

i

0.9

0.44

0.309

0.224

Voltage value [V] = U

i

25

28

30

35

Current value [A] = I

i

0.158

0.120

0.101

0.073

6.5.3. Operational data

The coils of type AC10 are available in two versions:
• Version for use with 300 Ω supply module (300 Ω barrier),
• Version for use with other authorized supply modules (e.g. 8 x remote

I/O from Stahl).

Version

Resis-

tance

R20 [Ω]

Minimum
clamping

voltage [V]

Minimum

current [mA]

Distinctive

code

number

Version which
uses 300

supply module

310

9

29

10

High-resis-
tance version

481

11.1

23

11

The maximum voltage and current values are specified by
the permitted electrical equipment.

6.5.4. Permitted ambient temperature

Montage

Temper-

ature class

AC10 - 5

AC10 - 6

Individual
assembly

T6

-40 ... +60 °C

-40 ... +60 °C

Block assembly

T6

-40 ... +60 °C

Not possible

Individual
assembly

T5

-40 ... +75 °C

-40 ... +75 °C

Block assembly

T5

-40 ... +75 °C

Not possible

Protection class:

For Ex “i” at least IP20 in accordance with
EN 60529 (DIN VDE 0470 Part 1)

english

PTB 01 ATEX 2101

Advertising