Burkert Type 6014 User Manual

Operating instructions type 6014

Advertising
background image

Operating Instructions

Type 6014

Design:
3-way solenoid valve, direct acting, normally closed (Circuit
function C), normally open (Circuit function D) or universal
function (Circuit function T).

Seal Materials and Fluids handled:
See Table 1.

Fluid and Ambient Temperature:
For Hazardous Locations Div. 1 (T4 rated)
Max. Ambient Temperature

104 °F (40 °C)

Max. Fluid Temperature

194 °F (90 °C)

The UL-listed valve for Hazardous Locations is suitable for the
fluids air, inert gas, water and gasoline.

For Hazardous Locations Div. 1 (T6 rated)
Max. Ambient Temperature

104 °F (40 °C)

Max. Fluid Temperature

140 °F (60 °C)

For Intrinsically Safe Apparatus for use in Class I, II and III,
Division 1 Hazardous Locations (T6 rated)
Max. Ambient Temperature

140 °F (60 °C)

Max. Fluid Temperature

140 °F (60 °C)

For Hazardous Locations Div. 2 and Ordinary Locations:
See Table 1.

Pressure Range:
Maximum inlet pressure see label on valve.

Installation:
Before installing valve ensure that piping etc. is free of foreign
matter (metal shavings, pipe sealing materials, welding scale
etc.). Installation as required but preferable with coil uppermost.
Installation in this position tends to prevent foreign matter
remaining in core tube (increased life). Do not put any loads on
coil unit.

PTFE tape is recommended for sealing ports. Mounting is
accomplished by means of four M4 x 8 mm tapped holes
located on the valve underside. Letters on valve body indicate
pressure port, exhaust and outlet of the valve.

Marking (example):

Body Material
BR

=

Brass

SS

=

Stainless Steel

Seal Material
EPDM =

EPDM

NBR

=

NBR

FKM

=

FKM

Circuit function
C =

Normally Closed

D =

Normally Open

T =

Universal Function

Item No.

Voltage / Frequency / Power Consumption

Maximum Pressure

Approvals
The valve is either approved as

General Purpose valve for Hazardous Locations

Class I, Division 1, Group A, B, C, D
Class II, Division 1, Group E, F, G
Class III, Division 1 and 2
Operating Temperature T 4

or

General Purpose valve for Hazardous Locations

Class I, Division 1, Group A, B, C, D
Class II, Division 1, Group E, F, G
Class III, Division 1 and 2
Operating Temperature T 6

or

Intrinsically Safe Apparatus for Hazardous Locations

Class I, Division 1, Group A, B, C, D
Class II, Division 1, Group E, F, G
Class III, Division 1
Operating Temperature T 6

or

FM approved as

Nonincendive for Hazardous Locations
Class I, Division 2, Group A, B, C, D
Class II, Division 2, Group F, G
Class III, Division 1 and 2
Operating Temperature T 4

UL listed for General Purpose
CSA approved for General Purpose

See label on the valve.

Table 1

Seal Materials

Seat / O-ring

Fluid

Temperatures [°F]

Buna “N”

Ethylene

FKM

NBR

Propylene (EPDM)

Air

Fluid Temp.

+ 14 to + 194

- 40 to + 266

+ 14 to + 266

Ambient

+ 14 to + 130

+ 14 to + 130

+ 14 to + 130

Water

Fluid Temp.

+ 32 to + 194

+ 32 to + 212

+ 32 to + 212

Ambient

+ 32 to + 130

+ 32 to + 130

+ 32 to +130

Neutral gas

Fluid Temp.

+ 14 to + 194

- 40 to + 266

+ 14 to + 266

Ambient

+ 14 to + 130

+ 14 to + 130

+ 14 to + 130

Light oil

Fluid Temp.

+ 14 to + 194

+ 14 to + 266

Ambient

+ 14 to + 130

+ 14 to + 130

Operating Instructions 0605/09_EN-EN_00893619

Advertising