Valve Construction

• 3/2 way pilot valve with various electrical connection possibilities
• valve body with diaphragm and seat seals (3/2 and 5/2), or with gate valve (5/3)
• 2(B) / 4 (A) service ports plus supply and venting ports 1 (P) / 3 (R) / 5 (S) with

internal G 1/4 thread

• as option, plug-in connectors for external 8 mm hose diameters for the service ports
• the valves can be mounted on the modular pneumatic basic rail Type MP07
• can be mounted in any position, preferably with the magnetic system at the top

3/2 way valve:

In de-energised position, Pressure Inlet 1 closed, Outlet Port 2 exhausted

3/2 way valve for vacuum, with auxiliary pilot air:

In de-energised position, Pressure Inlet 1 closed, Outlet Port 2 exhausted

3/2 way valve:

In de-energised position, Pressure Inlet 1 connected to Outlet Port 2

5/2 way valve:

In de-energised position, Pressure Inlet 1 connected to Outlet Port 2, Outlet Port 4 exhausted.

5/2 way valve:

Impulse drive model

Valve operations of the Type 6516 / 6517

NOTE

Plug-in connections only for the service ports 2 (B) and 4 (A).
The valves require no maintenance.

The vacuum generator must be connected to port 1!