2/2- and 3/2-way Rocker Solenoid Valve

with Medium Isolation
2/2- und 3/2-Wege Wippen-

Magnetventil mit Medientrennung
Electrovanne à bascule 2/2 et 3/2 voies

avec séparation des fluides

Address / Adresse

Germany / Deutschland / Allemagne
Bürkert Fluid Control Systems
Sales Center
Christian-Bürkert-Str. 13-17
D-74653 Ingelfingen
Tel. + 49 (0) 7940 - 10 91 111
Fax + 49 (0) 7940 - 10 91 448
E-mail: [email protected]

International
www.burkert.com → Bürkert → Company → Locations

Manuals and data sheets on the Internet : www.burkert.com
Bedienungsanleitungen und Datenblätter im Internet: www.buerkert.de
Instructions de service et fiches techniques sur Internet: www.buerkert.fr

© 2013 Bürkert Werke GmbH
Operating Instructions 1306/00_EU-ml_00810310 / Original DE

SYMBOLS

designates a procedure which you must carry out.

NOTE!

Warns of damage to property!
Failure to observe the warning may result in damage to

the device or the equipment.

Indicates important additional information, tips and

recommendations.

DARSTELLUNGSMITTEL

markiert einen Arbeitsschritt, den Sie ausführen müssen.

HINWEIS!

Warnt vor Sachschäden!

Bei Nichtbeachtung kann das Ventil oder die Anlage

beschädigt werden.

bezeichnet wichtige Zusatzinformationen, Tipps und

Empfehlungen.

SYMBOLES

identifie une opération que vous devez effectuer.

REMARQUE !

Met en garde contre des dommages matériels !
L’appareil ou l’installation peut être endommagé(e) en cas

de non-respect.

Désigne des informations supplémentaires importantes,

des conseils et des recommandations d’importance.

This supplementary sheet contains important information for the

use, installation and set-up of the solenoid valve Type 6624,

bistable variant (pulse).
Operating instructions and data sheet for the valve type still apply,

in particular the safety instructions and protective measures.

Magnetic force!

Never bring magnetically sensitive objects near the valve

(e.g. cards with magnetic strip).

A permanent magnet is installed in the valve. The magnetic force is

active even when the valve is switched off.

SET-UP AND INSTALLATION

• Distance between the individual valves: at least. 12 mm
• Distance between valve

and ferromagnetic parts:

at least. 6 mm

(e.g. magnetically conductive housing parts)

If these distances are not observed, the magnetic leakage flux may

cause malfunctions.
• Installation position: any
• Max. shock resistance: 20g

Standard set-up

(≥ 22)

(≥ 22)

≥12

≥12

Alternat. set-up: checkerboard

≥ 1

≥ 1

Overlapping

coils not

permitted!

R ≥ 20

45°

45 ° arrangement, minimum inner

radius for attachment bores

Alternative set-up:

star-shaped

Arrangement for angle X < 45°

≥ 12

ELECTRICAL CONNECTION

• Operating voltage: see rating plate.
• Protection class: 3 according to VDE 0580
• Current pulse length: 100 ... 250 ms

NOTE!

Damage to the valve!

Never simultaneously energize both positive terminals

on the valve. Pulses emitted simultaneously to both

connections will damage the valve.

1

Left connection (+)

(wire: red/black

rectangular connector: white)

2

Middle connection (–)

Negative terminal

3

Right connection (+)

(wire: red

rectangular connector: brown)

Never simultaneously

switch both positive

terminals!

1

2

3

Current pulse 100 - 250 ms

1

+

+

2 3

1

+

2 3

1

+ –

2 3

3/2-way

NC opened

NO closed

NC closed

NO opened

Damage to

the valve!

2/2-way

closed

opened

FLUIDIC DATA

See rating plate.