Burkert Type 8635 User Manual

Page 7

Advertising
background image

7

Particular safety instructions

PTB 04 ATEX 2027

4.2.4 cleaning in explosion-risk areas

Check that any cleaning agents are approved for use in
explosive atmospheres.

4.2.5 Type label for explosions-risk areas

II(1) 2G Ex ia IIC T6/T5/T4

IECEx PTB 04.0016

Ex ia IIC T6/T5/T4

Marking gas explosions protection

Ignition degree of protection

Gas group

Temperature class

IECEx approval number

IECEx marking

ATEX approval number

PTB 04 ATEX 2027

Fig. 1: Type label for explosions-risk areas

4.2.6 Temperature ranges in explosion-risk

areas

Ambient temperature
T4, T5:

-25 ... +65 °C

T6:

-25 ... +60 °C

4.2.7 Electrical data

The device in ignition degree of protection intrinsic safety Ex ia IIC,
may be connected only to intrinsically safe electric.
Explosion group

IIC

Category

ia

Temperature class

T4 / T5 / T6

english