Technical Data

6. TECHNICAL DATA

Explosion protection

Ex mb II T4

Rated voltage

250 V ≅

Rated current

0.032 ... 4A

Breaking capacity

1500 A, 250 V ≅

Ambient temperature

+ 50 °C

Temperature class

T4

Melting behaviour

F to DIN 41 660

7. INSTALLATION AND START-UP

7.1. Safety Instructions

DANGER!

Danger of explosion!
The device is a sealed system. If used in the EX area, there is a

danger of explosion if the system is opened during operation!
• The system must not be disassembled during operation.
Danger of explosion caused by electrostatic charge!
If there is a sudden discharge from electrostatically charged devices

or persons, there is a danger of explosion in the EX area.
• Take appropriate measures to prevent electrostatic charges in the

EX area.

• Clean the device surface by gently wiping it with a damp or

antistatic cloth

Risk of electric shock!
Acute risk of injury from hazardous structure-borne voltage!
Risk of damage to the device due to short circuit!
• Work on the electrical system may only be carried out by quali-

fied electricians.

• Before starting work, switch off the power supply and secure to

prevent it being switched on again!

• Observe the applicable accident prevention and safety regula-

tions for electrical devices!

• Only fit the fuse when undamaged and clean!
• To be noted when using the type 1058 fuse the characteristic

values on the fuse