Conditions of use – Burkert Type 8715 User Manual

Page 12

Advertising
background image

12

Technicaldata

Type 8700, 8701, 8703, 8705

8701 20.0 Nl/min

Made in France

00210166

W49MM

24V DC 5W DP

CH4

S/N 1004

FKM

Type of

device

Operating fluid

Materail of the seal

Supply voltage

Max. power

required

Output signal

Manufacturing

code

Bar code

Order code

of the device

Fig. 3: Detail of a name plat

Calibration date

Calibration

pressure

Mounting

position

Order code of the device

Calibration fluid

Calibration data

00182381

QC passed: 25/11/2011

P1 : 10,00 barg

Medium 1

P1 : 10,00 barg

Medium 2

Mounting: horizontal upright

Fig. 4: Details of a calibration plate

6.2.

conditions of use

Warning

risk of injury from malfunction due to effects of weather!
The MFM / MFC is not designed for unrestricted use outdoors.
• Protect the device from direct sunlight.
• Observe the ambient temperature permitted for the device.
• Protect the device from humidity.

setting

value

Ambient temperature

-10 °C to +55 °C
For UL devices: 0 °C to 40 °C

Fluid temperature

for oxygen: -10 °C to +60 °C

for the other fluids: -10 °C to +70 °C

Air humidity

< 95%, without condensation

Relative humidity for UL
devices

80% up to a temperature of 31°C, with

a linear decrease to a relative humidity of

50% at 40°C

Protection rating
acc. to EN 60529

Only if devices are cabled and the

connectors are plugged in and

tightened: IP40

Absolute height above
sea level for UL devices

2000 m max.

Operating environment

Indoors, with pollution degree 2

Serial

number

Nominal flow-rate (Q

nom

)

and unit flow-rate

English

Advertising
This manual is related to the following products: