20

danger

risk of injury due to electrical voltage.
• Shut down and isolate the electrical power source

before carrying out work on the system.

• Observe all applicable accident protection and safety

regulations for electrical equipment.

Warning

risk of injury due to non-conforming installation.
• The electrical and fluid installation can only be carried

out by qualified and skilled staff with the appropriate

tools.

• Observe mounting instructions of the fitting.
risk of injury due to an uncontrolled restart.
• Ensure that the restart of the installation is controlled

after any interventions on it.

English

21

Warning

risk of injury if the fluid pressure/ temperature
dependency is not respected.
• Take the fluid pressure / temperature dependency into

account according to the material of the fitting (see the

operating instructions of the fitting used).

• Comply with the Pressure Directive 97/23/EC.

Warning

risk of injury due to nonconforming commissioning.
Non conforming commissioning may lead to injuries and
damage the device and its surroundings.
• Before commissioning, make sure that the staff in

charge have read and fully understood the contents of

the manual.

• In particular, observe the safety recommendations and

intended use.

• The device / the installation must only be commissio-

ned by suitably trained staff.

English

21

22

note

risk of damage to the device due to the environment
• Protect this device against electromagnetic interfe-

rence, ultraviolet rays and, when installed outdoors, the

effects of the climatic conditions.

To make sure the device operates correctly, plug in
and tighten the connector.

installation onto the pipe

Choose a fitting appropriate to the velocity and the
flow rate of the fluid inside the pipe, refer to the fol-
lowing graphs (see Table 2). The graph is used to
determine the DN of the pipe and the fitting appropriate
to the application, according to the fluid velocity and
the flow rate.

Install the fitting on the pipe as described in the ope-
rating instructions of the fitting used.

English

23

Example:
• Specification:

- nominal flow: 10 m

3

/h,

- optimal flow velocity: between 2 and 3 m/s

• Solution: intersection between flow rate and flow velocity

in the graph gives the appropriate pipe diameter, DN40
(or DN50 for the asterisked fittings).

* For the fittings:
• with external thread connections acc. to SMS 1145,
• with welding end connections acc. to SMS 3008,

BS 4825 / ASME BPE or DIN 11850 Rg 2,

• Clamp according to SMS 3017 / ISO 2852 or BS 4825

/ ASME BPE or DIN 32676