3 mounting of the panel-mounted version, English – Burkert Type 8032 User Manual

Page 14

Advertising
background image

ENGLISH

ENGLISH

remote flow rate controller 8032

4.3 mounting of the panel-mounted version

1� Cut away, according to one of the drilling jig hereafter, the opening in the panel (thickness

between 1 and 3 mm) of the switch cabinet� Make sure to scrupulously respect the indicated
dimensions�

47,2 ±0,2

47,2 ±0,2

45

45

=

=

=

=

∅ 3 (x4)

R3-7 (x4)

∅ 3 (x4)

47,2 ±0,2

=

=

48

45°

45°

45°

47,2 ±0,2

=

=

45°

61,6

2� On the rear face of the electronic board, disconnect the 5 wires [1] by pressing the orange

locking levers with a screwdriver, then pull out flat cable [2]�

3� Unfasten the 4 screws [3] on the front face [4]�
4� Set front face [4] with seal [5] onto the opening, the electronic board facing the inside of the

cabinet�

5� On the rear side of the device, connect flat cable [2] back by maintening the front face and

4

installation

Minimal opening

Maximal opening

Advertising